首页 | 本学科首页   官方微博 | 高级检索  
     

低浓度对比剂在冠状动脉CTA检查中的可行性研究
引用本文:常 妙,李佩玲,初金刚,赵 宇,王丽洁,徐 克. 低浓度对比剂在冠状动脉CTA检查中的可行性研究[J]. 中国临床医学影像杂志, 2014, 25(3): 172-175
作者姓名:常 妙  李佩玲  初金刚  赵 宇  王丽洁  徐 克
作者单位:中国医科大学附属第一医院放射科,辽宁 沈阳 110001
摘    要:目的:探讨低浓度碘对比剂(270 mgI/mL)配合低管电压在冠状动脉CTA检查中的可行性。材料与方法:将90例行冠状动脉CTA检查的患者随机分为A组和B组。A组60例应用270 mgI/mL碘对比剂同时使用迭代算法重建,再将A组根据体质量指数(BMI)分为A1组(25例)及A2组(35例),A1组(BMI〈24 kg/m2)管电压为80 kV,A2组(BMI≥24 kg/m2)管电压为100 kV;B组30例应用370 mgI/mL碘对比剂,120 kV管电压。两组均采用前瞻性心电门控扫描。记录扫描辐射剂量,并对图像质量进行主、客观分析。结果:平均有效辐射剂量(ED)A1组为(2.00±0.56) mSv,A2组为(2.35±0.74) mSv,B组为(3.98±1.78) mSv,A1组与B组间及A2组与B组间均有统计学差异(t值分别为-5.34和-4.95,P〈0.05)。图像质量方面,A1组与B组间及A2组与B组间主观评价优秀率无统计学差异(χ2值分别为1.10和2.04,P值均〉0.05);客观评价图像噪声(SD)、信噪比(SNR)、对比噪声比(CNR)亦均无统计学差异。结论:应用尽可能低浓度的碘对比剂(270 mgI/mL)配合低管电压在冠状动脉CTA检查中是可行的,超重人群(BMI≥24 kg/m2)亦可应用,同时显著的降低了辐射剂量和碘注射量。

关 键 词:冠状动脉疾病  体层摄影术  X线计算机  冠状血管造影术
收稿时间:2013-07-09
修稿时间:2013-11-29

Feasibility of low concentration contrast medium in coronary CT angiography
CHANG Miao,LI Pei-ling,CHU Jin-gang,ZHAO Yu,WANG Li-jie,XU Ke. Feasibility of low concentration contrast medium in coronary CT angiography[J]. Journal of China Clinic Medical Imaging, 2014, 25(3): 172-175
Authors:CHANG Miao  LI Pei-ling  CHU Jin-gang  ZHAO Yu  WANG Li-jie  XU Ke
Affiliation:(Department of Radiology, the First Affiliated Hospital of China Medical University, Shenyang 110001, China)
Abstract:Objective: To explore the feasibility of using low concentration contrast medium(270 mgI/mL) with the low tube voltage in coronary artery CTA. Materials and Methods: Ninty patients with coronary CTA examination were divided into group A and group B randomly. Group A (n=60) used contrast medium of 270 mgI/mL with sinogram-affirmed iterative reconstruction(SAFIRE). Group A was further divided into group Al(n=25) and A2(n=35) according to body mass index(BMI). Group Al(BMI〈24 kg/m2) 80 kV was used for scanning, group A2(BMI≥24 kg/m2) 100 kV. The concentration of contrast medium and the tube voltage of group B (n=30) were 370 mgI/mL and 120 kV. All groups were scanned in prospective ECG-trigger gated. Radiation dose was recorded and image quality was analysed subjectively and objectively. Results: The effective dose (ED) of group A1, A2 and B were (2.00±0.56)mSv, (2.35±0.74)mSv and (3.98±1.78)mSv respectively, between group A1 and B, group A2 and B there were statistically significant(t=-5.34 and -4.95, P〈0.05). In image quality, there were no statistical differences between each groups in the excellent rate (x2=l.10 and 2.04, P〉0.05). The SD, SNR and CNR of images also showed no sta- tistical differences by objectively evaluated. Conclusion: Using low concentration contrast medium (270 mgI/mL) with low tube voltage in coronary artery CTA is feasible, especially in overweight(BMI≥24 kg/m2) population. At the same time, the radiation dose and concentration of iodine injection are reduced significantly.
Keywords:Coronary disease  Tomography, X-ray computed  Coronary angiography
本文献已被 CNKI 维普 等数据库收录!
点击此处可从《中国临床医学影像杂志》浏览原始摘要信息
点击此处可从《中国临床医学影像杂志》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号