探寻肺栓塞脉搏血氧饱和度的目标区间
引用本文:王洋,陈豪.探寻肺栓塞脉搏血氧饱和度的目标区间[J].协和医学杂志,2022,13(1):89-95.
作者姓名:王洋  陈豪
作者单位:1.重庆两江新区第一人民医院呼吸与危重症医学科,重庆 401121
基金项目:重庆市卫生健康委医学科研项目2022WSJK051
摘    要:目的 探讨肺栓塞患者氧疗期间脉搏血氧饱和度(pulse oxygen saturation,SpO2)与院内全因死亡风险的关系.方法 检索2014—2015年eICU数据库中美国多家医院以肺栓塞为主要诊断的病历资料.以院内全因死亡为因变量,氧疗期间中位SpO2为自变量构建广义相加模型(generalized addit...

关 键 词:脉搏血氧饱和度  肺栓塞  高氧血症  氧疗  死亡率
收稿时间:2021-02-21

The Search for Optimal Pulse Oxygen Saturation Targets in Pulmonary Embolism Patients
Institution:1.Pulmonary and Critical Care Medicine, First People's Hospital of Chongqing Liangjiang New Area, Chongqing 401121, China2.Pulmonary and Critical Care Medicine, Dianjiang People's Hospital, Chongqing 408300, China
Abstract:  Objective  To determine the association between pulse oximetry-derived oxygen saturation(SpO2) and all-cause in-hospital mortality of patients with pulmonary embolism during oxygen therapy.  Methods  Clinical data of the patients with pulmonary embolism as the primary diagnosis in different American medical institutions from the eICU database during 2014 to 2015 were retrieved. Generalized additive model (GAM) was constructed and the graph was drawn to analyze the association between median SpO2 and all-cause in-hospital mortality. The lowest and smooth area of the curve was the optimal SpO2 range. Moreover, the mult- ivariate Cox regression model was applied to verify the association between SpO2 level during oxygen therapy and all-cause in-hospital mortality of patients with pulmonary embolism.  Results  A total of 422 patients with pulmonary embolism that met the inclusion and exclusion criteria were enrolled. The median score of SpO2 was 97%(95%, 98%) during oxygen therapy.A total of 336 (79.6%) patients were discharged from the hospital and 86 (20.4%) patients died. The GAM indicated a U-shaped relationship between the median score of SpO2 and all-cause in-hospital mortality in patients with pulmonary embolism. In addition, the lowest mortality was observed when the SpO2 range was 96%-98%. Multivariable Cox regression analysis confirmed that the SpO2 level was independently associated with decreased mortality. Taking patients with median SpO2 rang of 96% to 98% as controls, the risk of all-cause in-hospital mortality was increased by 129.8% in patients with median SpO2 < 96% (HR=2.298, 95% CI: 1.268-4.163, P=0.006) and 77.3% in patients with median SpO2 > 98% (HR=1.773, 95% CI: 1.068-2.942, P=0.027).  Conclusions  The relationship between SpO2 levels and all-cause in-hospital mortality followed a U-shaped curve in patients with pulmonary embolism. The risk of all-cause in-hospital mortality was lowest when SpO2 was between 96% to 98% during oxygen therapy, which may be the target range of oxygenation.
Keywords:
点击此处可从《协和医学杂志》浏览原始摘要信息
点击此处可从《协和医学杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号