首页 | 本学科首页   官方微博 | 高级检索  
检索        

多媒体信息技术在头颈部恶性肿瘤精确放疗中的应用
引用本文:惠华,王强,崔连环,张涛,王敏,耿冲,杜傲男,孙建伟.多媒体信息技术在头颈部恶性肿瘤精确放疗中的应用[J].中国辐射卫生,2022,31(2):239-244.
作者姓名:惠华  王强  崔连环  张涛  王敏  耿冲  杜傲男  孙建伟
作者单位:徐州市肿瘤医院,江苏 徐州 221005
基金项目:江苏省六大高峰人才资助课题(YY-156)
摘    要:目的 探讨多媒体信息技术对头颈部恶性肿瘤(head and neck malignant tumors,HNT)精确放疗的影响。方法 选取2016—2019年HNT患者96例,随机分为实验组A组和对照组B组,同一固定体位方法、治疗医师及技师,分别应用多媒体信息技术、常规方法,施行医学科普、个体化教育、医患沟通后放疗定位、摆位。调查医疗依从性、观察放疗反应、分析摆位误差、记录占机时间。结果 依从性A组96.5% > B组73.8%,差异有统计学意义(P < 0.05);皮肤急性放射反应A组 < B组,差异有统计学意义(P < 0.05)。三维绝对摆位误差:A组(0.69 ±0.29) mm、(0.97 ±0.69) mm、(0.79 ±0.47) mm < B组(1.39 ±0.81) mm、(1.87 ±1.19) mm、(2.50 ±0.99) mm,差异有统计学意义(P < 0.05);三维传统摆位误差:A组(0.73 ±0.39) mm、(0.51 ±0.69) mm、(0.74 ±0.17) mm < B组(1.32 ±0.76) mm、(1.89 ±1.21) mm、(1.37 ±0.57) mm,差异有统计学意义(P < 0.05)。定位占机时间A组(145.15 ±28.45) s < B组(240.38 ±50.45) s,差异有统计学意义(P < 0.05);摆位占机时间A组(115.15 ±18.45) s < B组(173.38 ±24.45) s,差异有统计学意义(P < 0.05)。结论 应用多媒体信息技术对HNT精确放疗患者施行医学科普、个体化教育、医患沟通,可提高患者依从性,减轻急性放射反应,降低摆位误差,缩短定、摆位占机时间。

关 键 词:多媒体信息技术  肿瘤精确放疗  依从性  急性放射反应  摆位误差  占机时间  
收稿时间:2021-09-13

Application of multimedia information technology on precision radiotherapy for patients with head and neck malignant tumors
HUI Hua,WANG Qiang,CUI Lianhuan,ZHANG Tao,WANG Min,GENG Chong,DU Aonan,SUN Jianwei.Application of multimedia information technology on precision radiotherapy for patients with head and neck malignant tumors[J].Chinese Journal of Radiological Health,2022,31(2):239-244.
Authors:HUI Hua  WANG Qiang  CUI Lianhuan  ZHANG Tao  WANG Min  GENG Chong  DU Aonan  SUN Jianwei
Institution:Xuzhou Cancer Hospital, Xuzhou 221005 China
Abstract:Objective To investigate the effects of multimedia information technologies on precision radiotherapy of head and neck malignant tumors (HNT).Methods A total of 96 patients with HNT recruited from 2016 to 2019 were randomly assignedto group A and group B with the same planning methodand therapists/technicians. Conventional and multimedia information technologies were respectively used in group A and group B for medical science popularization, individualized education, and doctor-patient communication before radiotherapy planning and positioning. Medical compliance, radiotherapy responses, setup errors, and machine occupancy time were investigated.Results Medical compliance was significantly higher (P < 0.05) in group A (96.5%) than in group B (73.8%). Skin acute radiation reaction was significantly lower (P < 0.05) in group A than in group B. Three-dimensional absolute setup errors were 0.69 ±0.29 mm, 0.97 ±0.69 mm, and 0.79 ±0.47 mm in group A, which were significantly lower than 1.39 ±0.81 mm, 1.87 ±1.19 mm, and 2.50 ±0.99 mm in group B(P < 0.05). Traditional three-dimensional setup errors were 0.73 ±0.39 mm, 0.51 ±0.69 mm, and 0.74 ±0.17 mm in group A, which were significantly lower than 1.32 ±0.76 mm, 1.89 ±1.21 mm, and 1.37 ±0.57 mm in group B (P < 0.05). Planning time was 145.15 ±28.45 sin group A, which was significantly lower than 240.38 ±50.45 sin group B (P < 0.05). Positioning time was 115.15 ±18.45 s in group A, which was significantly lower than 173.38 ±24.45 sin group B (P < 0.05).Conclusion The application of multimedia information technologies inmedical science popularization, individualized education, and doctor-patient communication forpatients who received precision radiotherapy for HNT can significantly increase patient compliance, alleviate acute radiation reactions, reduce setup errors, and shorten the machine occupancy time of planning and positioning.
Keywords:Multimedia information technology  Precision radiotherapy fortumors  Compliance  Acute radiation reactions  Setup error  Machine occupancy time  
点击此处可从《中国辐射卫生》浏览原始摘要信息
点击此处可从《中国辐射卫生》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号