全自动胎儿肺部超声分析预测妊娠晚期胎儿肺成熟度的研究
引用本文:董亚青,高志敏,徐然,陈立芳,袁静,王明荣. 全自动胎儿肺部超声分析预测妊娠晚期胎儿肺成熟度的研究[J]. 河北医科大学学报, 2022, 43(10): 1192-1196. DOI: 10.3969/j.issn.1007-3205.2022.10.016
作者姓名:董亚青  高志敏  徐然  陈立芳  袁静  王明荣
作者单位:1.河北中石油中心医院超声医学科,河北 廊坊065000;2.河北中石油中心医院产科,河北 廊坊 065000
基金项目:廊坊市科学技术研究与发展计划项目(2020013132)
摘    要:目的 探讨全自动胎儿肺部超声分析预测妊娠晚期胎儿肺成熟度的应用价值。方法 选取在我院分娩的80例单胎孕妇,给予全自动胎儿肺部超声分析,比较新生儿呼吸窘迫综合征(neonatal respiratory distress syndrome,NRDS)和非NRDS肺部超声参数差异。结果 80例新生儿中,有34例发生NRDS;NRDS新生儿左肺容积(left lung volume,LLV)、右肺容积(right lung volume,RLV)、总肺容积(total lung volume,TLV)和TLV/体质量比值(fetal lung to body weight ratio,FLB)分别为(33.03±3.75)cm3、(44.07±3.16)cm3、(75.57±4.69)cm3和(0.25±0.04)cm3/10 g,明显低于非NRDS新生儿(35.12±2.84)cm3、(46.68±3.19)cm3、(81.95±6.03)cm3和(0.28±0.05)cm3/10 g。(P<0.05)。NRDS新生儿肺动脉血流参数搏动指数(pulsatile index,PI)和阻力指数(resistance index,RI)分别为(2.14±0.29)和(0.92±0.12),明显高于非NRDS新生儿(2.00±0.28)和(0.83±0.08)(P<0.05)。PI、RI与LLV、RLV、TLV无明显相关性(P>0.05),而PI、RI与FLB呈负相关(r=-0.485,-0.401,P<0.05)。全自动胎儿肺部超声预测胎儿肺成熟的敏感度、特异度、准确度、阳性预测值和阴性预测值分别为91.18%、91.30%、91.25%、88.57%和93.33%。结论 全自动胎儿肺部超声分析能有效预测妊娠晚期胎儿肺成熟度,值得临床使用。

关 键 词:妊娠末期  胎儿肺成熟度  超声检查  

Prediction of fetal lung maturity in late pregnancy by automatic ultrasound analysis of the fetal lung
DONG Ya-qing,GAO Zhi-min,XU Ran,CHEN Li-fang,YUAN Jing,WANG Ming-rong. Prediction of fetal lung maturity in late pregnancy by automatic ultrasound analysis of the fetal lung[J]. Journal of Hebei Medical University, 2022, 43(10): 1192-1196. DOI: 10.3969/j.issn.1007-3205.2022.10.016
Authors:DONG Ya-qing  GAO Zhi-min  XU Ran  CHEN Li-fang  YUAN Jing  WANG Ming-rong
Affiliation:1.Department of Ultrasound Medicine, Hebei Petro China Central Hospital, Langfang 065000, China;
2.Department of Obstetrics, Hebei Petro China Central Hospital, Langfang 065000, China

Abstract:Objective To explore the application value of automatic ultrasound analysis of the fetal lung in predicting fetal lung maturity in late pregnancy.Methods A total of 80 singleton pregnant women delivered in our hospital were given automatic ultrasound analysis of the fetal lung to compare the differences of pulmonary ultrasound parameters between neonatal respiratory distress syndrome(NRDS) and non-NRDS.Results Among 80 newborns, 34 cases developed NRDS. The left lung volume(LLV), right lung volume(RLV), total lung volume(TLV) and fetal lung to body weight ratio(FLB) of NRDS newborns were (33.03±3.50) cm3,(44.07±3.16)cm3,(75.57±4.69)cm3and (0.25±0.04)cm3/10 g, respectively, which were significantly lower than those of non NRDS newborns [(35.12±2.84) cm3, (46.68±3.19) cm3, (81.95±6.03) cm3 and (0.28±0.05) cm3/10 g, respectively]. (P<0.05). The pulsatile index (PI) and resistance index (RI) of pulmonary artery blood flow parameters in NRDS newborns were (2.14±0.29) and (0.92±0.12) respectively, which were significantly higher than those in non-NRDS newborns [(2.00±0.28) and (0.83±0.08)](P<0.05). There was no significant correlation between PI, RI and LLV, RLV and TLV (P>0.05), but there was a negative correlation between PI, RI and FLB (r=-0.485 and -0.401, P<0.05). The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of automatic ultrasound of the fetal lung in predicting fetal lung maturity were 91.18%, 91.30%, 91.25%, 88.57% and 93.33%, respectively.Conclusion Automatic ultrasound analysis of the fetal lung can effectively predict fetal lung maturity in late pregnancy, which is worthy of clinical use.
Keywords:late pregnancy   ultrasonography   fetal lung maturity  