Image quality of ct angiography using model-based iterative reconstruction in infants with congenital heart disease: Comparison with filtered back projection and hybrid iterative reconstruction
Affiliation:1. Massachusetts General Hospital, Department of Radiology, Boston, MA, United States;2. Greensboro Radiology Medical Imaging Professionals, Greensboro, NC, United States;3. Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, PA, United States;1. Department of Diagnostic and Interventional Radiology, University hospital RWTH Aachen, Pauwelsstrasse 30, Aachen 52074, Germany;2. Computed Tomography, Siemens Medical Healthcare, Forchheim, Germany;3. Department of Diagnostic and Interventional Radiology, Charite University Hospital, Berlin University, Berlin, Germany;4. Department of Diagnostic and Interventional Radiology, University Hospital, Philipps University Marburg, Marburg, Germany
Abstract:PurposeTo compare the image quality, rate of coronary artery visualization and diagnostic accuracy of 256-slice multi-detector computed tomography angiography (CTA) with prospective electrocardiographic (ECG) triggering at a tube voltage of 80 kVp between 3 reconstruction algorithms (filtered back projection (FBP), hybrid iterative reconstruction (iDose4) and iterative model reconstruction (IMR)) in infants with congenital heart disease (CHD).MethodsFifty-one infants with CHD who underwent cardiac CTA in our institution between December 2014 and March 2015 were included. The effective radiation doses were calculated. Imaging data were reconstructed using the FBP, iDose4 and IMR algorithms. Parameters of objective image quality (noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR)); subjective image quality (overall image quality, image noise and margin sharpness); coronary artery visibility; and diagnostic accuracy for the three algorithms were measured and compared.ResultsThe mean effective radiation dose was 0.61 ± 0.32 mSv. Compared to FBP and iDose4, IMR yielded significantly lower noise (P < 0.01), higher SNR and CNR values (P < 0.01), and a greater subjective image quality score (P < 0.01). The total number of coronary segments visualized was significantly higher for both iDose4 and IMR than for FBP (P = 0.002 and P = 0.025, respectively), but there was no significant difference in this parameter between iDose4 and IMR (P = 0.397). There was no significant difference in the diagnostic accuracy between the FBP, iDose4 and IMR algorithms (χ2 = 0.343, P = 0.842).ConclusionsFor infants with CHD undergoing cardiac CTA, the IMR reconstruction algorithm provided significantly increased objective and subjective image quality compared with the FBP and iDose4 algorithms. However, IMR did not improve the diagnostic accuracy or coronary artery visualization compared with iDose4.
Keywords:Congenital heart disease  Multidetector CT  Hybrid iterative reconstruction  Iterative model reconstruction
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号