首页 | 本学科首页   官方微博 | 高级检索  
     


Development of Diagnostic Reference Levels Using a Real-Time Radiation Dose Monitoring System at a Cardiovascular Center in Korea
Authors:Jungsu Kim  Deoknam Seo  Inseok Choi  Sora Nam  Yongsu Yoon  Hyunji Kim  Jae Her  Seonggyu Han  Soonmu Kwon  Hunsik Park  Dongheon Yang  Jungmin Kim
Affiliation:1. Department of Radiologic Science, College of Health Science, Korea University, #219, Holim Building, Korea Univ. health science Univ., Jeongneung 3-dong, Seongbuk-gu, Seoul, South Korea, 136-703
3. Department of Radio-technology, Wonkwang Health Science University, Jeonbuk-do, Republic of Korea
6. Department of Diagnostic Radiology, Korea Institute of Radiological & Medical Sciences, Seoul, Republic of Korea
8. Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
9. Medical Radiation TF Team, Center for Disease Prevention, Korea Centers for Disease Control and Prevention, Chungcheongbuk-do, Republic of Korea
2. Department of Radiologic Science, College of Medical Science, Catholic University of Daegu, Daegu, Republic of Korea
7. Department of Radiologic Technology, Daegu Health College, Daegu, Republic of Korea
4. Department of Internal Medicine, Kyungpook National University School of Medicine, Daegu, Republic of Korea
5. Department of Heart & Brain Attack Center, Kyungpook National University Hospital, Daegu, Republic of Korea
Abstract:Digital cardiovascular angiography accounts for a major portion of the radiation dose among the examinations performed at cardiovascular centres. However, dose-related information is neither monitored nor recorded systemically. This report concerns the construction of a radiation dose monitoring system based on digital imaging and communications in medicine (DICOM) data and its use at the cardiovascular centre of the University Hospitals in Korea. The dose information was analysed according to DICOM standards for a series of procedures, and the formulation of diagnostic reference levels (DRLs) at our cardiovascular centre represents the first of its kind in Korea. We determined a dose area product (DAP) DRL for coronary angiography of 75.6 Gy cm2 and a fluoroscopic time DRL of 318.0 s. The DAP DRL for percutaneous transluminal coronary intervention was 213.3 Gy cm2, and the DRL for fluoroscopic time was 1207.5 s.
Keywords:DICOM MPPS   Radiation dose monitoring   Cardiovascular centre   Diagnostic reference levels   Order communication system
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号