A modified implant healing abutment to optimize soft tissue contours: a case report |
| |
Authors: | Pow Edmond H N McMillan Anne S |
| |
Affiliation: | Oral Rehabilitation, Faculty of Dentistry, University of Hong Kong, Hong Kong. |
| |
Abstract: | The soft tissue profile created around a conventional healing abutment may be inadequate to accommodate an anatomically shaped abutment that is larger than a standard machined abutment. This causes difficulties in its insertion and subsequent impression-making and provisional restoration fabrication. This article presents a simple technique to overcome these problems. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|