双能量骨髓成像技术诊断骨髓水肿临床应用
引用本文:王少青,姜兴岳. 双能量骨髓成像技术诊断骨髓水肿临床应用[J]. 影像研究与医学应用, 2022, 0(3): 7-10
作者姓名:王少青  姜兴岳
作者单位:滨州医学院;滨州市人民医院;滨州医学院附属医院
摘    要:目的:使用西门子第三代双源CT(SOMATOM Force)探讨彩色编码双能量骨髓分析VNCa图像诊断骨髓水肿范围面积的临床应用.方法:选取滨州市人民医院2019年11月—2021年9月收治的因急症外伤行下肢骨关节检查的患者34例.患者均行双能量CT及MR扫描,两种检查间隔时间不超过7?d.采用双盲法由两名主治及以上医...

关 键 词:计算机断层扫描  双能计算机断层扫描  磁共振成像  下肢  骨髓水肿

Clinical application of dual energy bone marrow imaging technique in diagnosis of bone marrow edema
WANG Shaoqing,JIANG Xingyue. Clinical application of dual energy bone marrow imaging technique in diagnosis of bone marrow edema[J]. Journal of Imaging Research and Medical Applications, 2022, 0(3): 7-10
Authors:WANG Shaoqing  JIANG Xingyue
Affiliation:(Binzhou Medical University,Yantai,Shandong 264003,China;Binzhou People's Hospital,Binzhou,Shandong 256600,China;Binzhou Medical University Hospital,Binzhou,Shandong 256600,China)
Abstract:Objective To explore the clinical application of color coded dual-energy bone marrow analysis VNCa image in the diagnosis of bone marrow edema using Siemens third generation dual-source CT(SOMATOM Force).Methods A total of 34 patients were selected from Binzhou People's Hospital from November 2019 to September 2021 for bone and joint examination of lower limbs due to emergency trauma.All patients underwent dual-energy CT and MR scan,and the interval between the two examinations was no more than 7 days.The presence of bone marrow edema in dual-energy CT and magnetic resonance images was diagnosed by two attending and above physicians in a double-blind method(0=absence of bone marrow edema,1=presence of bone marrow edema).By another radiology attending physicians blinded and above high qualification diagnosis randomly selected CT and MRI scanning images,respectively in the coronal,sagittal and transverse position measuring bone marrow edema range of three biggest continuous level,and then respectively on the bone marrow edema area average and divided into dual-source CT images and MR images in the two groups,statistical analysis comparison of differences between the two groups.Results There were 24 cases of bone marrow edema(74 areas)in 34 patients(532 areas),22 cases of bone marrow edema(sensitivity 87.50%,specificity 90.00%)and 70 areas of bone marrow edema(sensitivity 85.14%,specificity 98.47%)diagnosed by dual-energy bone marrow imaging.Conclusion Dual-energy bone marrow imaging can effectively diagnose and evaluate the extent and area of bone marrow edema.
Keywords:Computed tomography  Dual-energy computed tomography  Magnetic resonance imaging  Lower extremity  Bone marrow edema