首页 | 本学科首页   官方微博 | 高级检索  
检索        


The effect of excitation laser power in Raman spectroscopic measurements of the degree of conversion of resin composites
Institution:1. Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, Zagreb, Croatia;2. Department of Physics and Biophysics, School of Medicine, University of Zagreb, Salata 3b, Zagreb, Croatia;3. Center of Excellence for Advanced Materials and Sensing Devices, Research Unit New Functional Materials, Bijenicka cesta 54, Zagreb, Croatia;4. Community Health Center, Zagreb, Croatia;5. Private Dental Office, Sisak, Croatia
Abstract:ObjectivesTo evaluate the effect of excitation laser power in Raman spectrometry by comparing the spectra and the degree of conversion (DC) values obtained using excitation powers between 300 and 1000 mW.MethodsFive commercial and three experimental resin composites were light cured at 1200 mW/cm2 for 10–20 s from a commercial blue-violet LED dental curing unit. Raman spectra were collected from composite specimens within 9 min after light-curing. The excitation laser (1064 nm) was focused on the spot of 0.4 mm in diameter. The following powers were used for specimen excitation (mW): 300, 400, 600, 800, and 1000. From Raman spectra, the DC values were calculated and compared among different laser powers. Also, vector-normalized Raman spectra collected using the lowest excitation power (300 mW) were compared to those collected using the maximum excitation power (1000 mW).ResultsVarying the excitation laser power between 300 and 1000 mW resulted in statistically significant differences in both the DC values and the intensity of particular spectral features. The effect of varying laser power on Raman spectra and obtained DC values was material-dependent. The DC values measured within an individual material using different laser powers varied between 3.2 and 7.2% (absolute DC difference). The spectral bands affected by variations in laser power were assigned to symmetric and asymmetric stretching of ?CH2 (2900-3100 cm?1), symmetric stretching of aliphatic Cdouble bondC (1640 cm?1) and scissoring of C–H (1458 cm?1).SignificanceThe DC can be artificially elevated through increasing excitation laser power. This effect should be considered in Raman spectroscopic evaluations of DC in specimens during ongoing post-cure polymerization.
Keywords:Raman spectroscopy  FT-Raman  Laser power  Degree of conversion  Resin composites
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号