"Worst case" aerosol testing parameters: I. Sodium chloride and dioctyl phthalate aerosol filter efficiency as a function of particle size and flow rate
Authors:G A Stevens  E S Moyer
Institution:National Institute for Occupational Safety and Health, Division of Safety Research, Morgantown, WV 26505-2888.
Abstract:The efficiency of filter media is dependent on the characteristics of the challenge aerosol and the filter's construction. Challenge aerosol parameters, such as particle size, density, shape, electrical charge, and flow rate, are influential in determining the filter's efficiency. In this regard, a so-called "worst case" set of conditions has been proposed for testing respirator filter efficiency in order to ensure wearer protection. Data collected on various types of filters (dust and mist; dust, fume, and mist; paint, lacquer, and enamel mist; and high efficiency) challenged with a worst case-type sodium chloride (NaCl) and dioctyl phthalate (DOP) aerosol are presented. The particle size of maximum penetration varies as a function of filter type and was less than 0.25-micron count mean diameter (CMD) in all cases. The count efficiency for high efficiency filters was greater than 99.97% at worst case testing conditions, but the worst case count efficiencies for dust and mist; dust, fume and mist; and paint, lacquer and enamel mist filters were not nearly as efficient as existing test methods indicate. Also, as the test flow rate is increased, the count efficiency decreases. Thus, respirator filters were found to conform to the prediction of single-fiber filtration theory.