Accuracy of the convolution/superposition dose calculation algorithm at the condition of electron disequilibrium
Authors:Chao-Yuan Huang   Tieh-Chi Chu   Sung-Yen Lin   Jao-Perng Lin  Chang-Yao Hsieh
Affiliation:

a Department of Oncology, National Taiwan University Hospital, 7, Chung San South Road, Taipei, Taiwan, ROC

b Department of Nuclear Science, National Tsing Hua University, 300, Hsinchu, Taiwan, ROC

c Department of Radiation Oncology, Changhua Christian Hospital, 500, Changhua, Taiwan, ROC

Abstract:Using Monte Carlo simulation and the convolution/superposition algorithm, this work examines percent depth dose curves of the central axis in an acrylic phantom (20×20×20 cm3) with variously sized air cavities (20×20×1.0, 20×20×2.0, 20×20×3.0, 20×20×4.0 and 20×20×4.95 cm3 for study of longitudinal electron disequilibrium (ED) and 3.6×3.6×4.95, 4.5×4.5×4.95, 5.4×5.4×4.95 and 20×20×4.95 cm3 for study of lateral ED). Radiochromic film samples are also measured to verify the Monte Carlo results. The Monte Carlo simulation is performed using OMEGA/BEAM and DOSXYZ codes, and the convolution/superposition calculation relies on an ADAC commercial treatment planning system.

Underestimating the dose kernel expansion leads to overestimating the dose of what was found in the air cavity of ED using the convolution/superposition algorithm. Consequently, the dose in the rebuild-up region is influenced. The influenced region is on the acrylic phantom surface to a depth of about 0.5 cm. The density scaling method of the convolution/superposition algorithm, applied to heterogeneous media, should be enhanced to account for the over-expansion of the dose kernel in the cavity of ED.

Keywords:Monte Carlo simulation   Convolution/superposition algorithm   Percent depth dose curve   OMEGA/BEAM   DOSXYZ   Electron disequilibrium