Peripheral arterial coil embolization for hepatic arteriovenous malformation in Osler-Weber-Rendu disease; useful for controlling high output heart failure, but harmful to the liver |
| |
Authors: | Hisamatsu K Ueeda M Ando M Koike K Matsuo N Matsu-ura K Ueda H Hirohata M Imai M |
| |
Institution: | Department of Internal Medicine, Mitoyo General Hospital, Mitoyo-gun, Kanagawa. |
| |
Abstract: | A 55-year-old Japanese housewife, who had Osler-Weber-Rendu disease, was admitted to our hospital because of frequent epistaxis and worsening exertional dyspnea. The computed tomography and hepatic arteriography revealed large hepatic arteriovenous malformation, which was considered to be the leading cause of her high output heart failure. Two series of hepatic arterial coil embolization procedures were performed to reduce hepatic shunt flow. They temporarily improved her cardiac condition, but gradually induced progressive hepatic failure due to intrahepatic cholangitis. Hepatic dysfunction restricted her quality of life and lead to a fatal clinical course one year after the second coil embolization. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|