The depth of the lumbar epidural space from the skin
Authors:G.R. Harrison  BSc  MB  BS  FFARCS  Senior Registrar   N.W.B. Clowes  MB  ChB  FFARCS  Senior Registrar
Affiliation:Department of Anaesthetics, City General Hospital, London Road, Stoke on Trent.
Abstract:The depth of the epidural space at different intervertebral interspaces was measured in 1000 parturients. Overall the median distance from the skin to the epidural space was 4.7 cm, but this varied with the lumbar interspace at which it was measured, being greatest at the third (L3-4) interspace (4.93 cm) and least at the first (L1-2) interspace (4.23 cm). The clinical significance of these findings is discussed.
Keywords:Anaesthetic techniques   epidural