首页 | 本学科首页   官方微博 | 高级检索  
     


Brain death in infants: evaluation with Doppler US
Authors:Glasier, CM   Seibert, JJ   Chadduck, WM   Williamson, SL   Leithiser, RE, Jr
Affiliation:Department of Radiology, University of Arkansas for Medical Sciences, Little Rock.
Abstract:In a preliminary study, nine infants with a clinically determined diagnosis of brain death were examined with duplex pulsed Doppler ultrasonography (US) through the anterior fontanelle. Flow velocity measurements were made in the intracranial internal carotid artery and anterior cerebral artery. Resistive index (RI) was calculated in each patient and used as an indicator of diastolic flow. Eight of nine infants showed markedly elevated RI (100%-191%) with reversal of diastolic flow. One infant had low RI (42%-58%) with preserved systolic and diastolic flow until death. The authors believe that the elevation of RI with diastolic flow reversal seen in these patients is a reflection of increased intracranial pressure and is a sign of poor prognosis when present on serial examinations. Cranial duplex pulsed Doppler US is a useful, noninvasive tool in the diagnosis of brain death in infants but must be carefully correlated with clinical examination and other diagnostic tests.
Keywords:
点击此处可从《Radiology》浏览原始摘要信息
点击此处可从《Radiology》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏