首页 | 本学科首页   官方微博 | 高级检索  
     


Evaluation of Precision and Accuracy Assessment of Different 3-D Surface Imaging Systems for Biomedical Purposes
Authors:Maximilian Eder  Gernot Brockmann  Alexander Zimmermann  Moschos A. Papadopoulos  Katja Schwenzer-Zimmerer  Hans Florian Zeilhofer  Robert Sader  Nikolaos A. Papadopulos  Laszlo Kovacs
Affiliation:1. Department of Plastic Surgery and Hand Surgery, Klinikum rechts der Isar, Technische Universit?t München, Ismaninger Strasse 22, 81675, München, Germany
2. Department of Vascular Surgery, Klinikum rechts der Isar, Technische Universit?t München, Ismaningerstr. 22, 81675, München, Germany
3. Department of Orthodontics, School of Dentistry, Aristotle University of Thessaloniki, 54124, Thessaloniki, Greece
4. Division of Cranio-maxillo-facial Surgery, Department of Reconstructive Surgery, University of Basel, Spitalstrasse 21, 4031, Basel, Switzerland
5. Department of Oral, Maxillofacial, and Plastic Facial Surgery, Goethe Universit?t Frankfurt, Theodor-Stern-Kai 7, 60596, Frankfurt am Main, Germany
Abstract:Three-dimensional (3-D) surface imaging has gained clinical acceptance, especially in the field of cranio-maxillo-facial and plastic, reconstructive, and aesthetic surgery. Six scanners based on different scanning principles (Minolta Vivid 910®, Polhemus FastSCAN™, GFM PRIMOS®, GFM TopoCAM®, Steinbichler Comet® Vario Zoom 250, 3dMD DSP 400®) were used to measure five sheep skulls of different sizes. In three areas with varying anatomical complexity (areas, 1 = high; 2 = moderate; 3 = low), 56 distances between 20 landmarks are defined on each skull. Manual measurement (MM), coordinate machine measurements (CMM) and computer tomography (CT) measurements were used to define a reference method for further precision and accuracy evaluation of different 3-D scanning systems. MM showed high correlation to CMM and CT measurements (both r = 0.987; p < 0.001) and served as the reference method. TopoCAM®, Comet® and Vivid 910® showed highest measurement precision over all areas of complexity; Vivid 910®, the Comet® and the DSP 400® demonstrated highest accuracy over all areas with Vivid 910® being most accurate in areas 1 and 3, and the DSP 400® most accurate in area 2. In accordance to the measured distance length, most 3-D devices present higher measurement precision and accuracy for large distances and lower degrees of precision and accuracy for short distances. In general, higher degrees of complexity are associated with lower 3-D assessment accuracy, suggesting that for optimal results, different types of scanners should be applied to specific clinical applications and medical problems according to their special construction designs and characteristics.
Keywords:Accuracy   Biomedical   Fringe projection   Laser scanning   Precision   Stereo-photogrammetry   Surface imaging   3D
本文献已被 SpringerLink 等数据库收录!