摘    要:目的:探讨放射性核素99mTc-DTPA肾动态显像对静脉肾盂造影(IVP)不显影患肾功能评价的临床意义。方法:受检者共64例,临床诊断共66只患肾。99mTc-DTPA静脉注射后SPECT肾动态显像,获取血流灌注和功能显像图像并测定分肾GFR值。结果:IVP不显影的患肾99mTc-DTPA动态显像结果表现为0级2例,GFR均值为53.7ml/min;I级3例,GFR均值为35.8ml/min;II级7例,GFR均值为21.1ml/min;III级36例,GFR均值12.8ml/min;IV级18例,GFR均值为7.8ml/min。对99mTc-DTPA动态显像提示另一肾脏功能正常或轻度受损的患者手术切除患肾20例,其余行保留肾脏治疗手段,大部分功能恢复良好。结论:99mTc-DTPA肾动态显像对评价肾功能,特别是对IVP不显影的单肾功能判定有重要的临床价值,此法具有简便、无创伤、灵敏度高及可重复性的特点。

关 键 词:99m锝五乙酸盐;肾疾病;放射性核素显像
文章编号:1008-1062(2007)07-0479-03
收稿时间:2007-01-15
修稿时间:2007-01-152007-04-05

Study of 99mTc-DTPA renal dynamic imaging for renal function as IVP detection failed
JIANG Ning-yi,LIU Xiong-ying,HU Ying-ying,ZHANG Hong,LIU Sheng,LIANG Jiu-gen,LU Xian-ping,LIU Xing-guang,CHEN Shao-xiong. Study of 99mTc-DTPA renal dynamic imaging for renal function as IVP detection failed[J]. Journal of China Clinic Medical Imaging, 2007, 18(7): 479-481
Authors:JIANG Ning-yi  LIU Xiong-ying  HU Ying-ying  ZHANG Hong  LIU Sheng  LIANG Jiu-gen  LU Xian-ping  LIU Xing-guang  CHEN Shao-xiong
Affiliation:1. Department of Nuclear Medicine, the Second Affiliated Hospital of Sun Yat-sen University, Guangzhou 510120, Chino; 2. The First Affiliated Hospital of Guangdong Pharmaceutical University, Guangzhou 510080, China
Abstract:Objective: To investigate the clinical significance of ~(99m)Tc-DTPA renal dynamic imaging in evaluating renal function as intravenous pyelography(IVP) detection failed. Methods: Sixty-six abnormal kidneys in 64 patients which IVP detection failed were accepted for ~(99m)Tc-DTPA renal dynamic imaging. Results: ~(99m)Tc-DTPA renal dynamic imaging demonstrated that all the IVP detection failed kidneys had poor function and nonfunction, detailed as: grade 0 in 2 cases, grade I in 3 cases, grade II in 7 cases, grade III in 36 cases, grade IV in 18 cases. And the average GFR was 53.7ml/min, 35.8ml/min, 21.1ml/min, 12.8ml/min and 7.8ml/min respectively. Twenty cases which ~(99m)Tc-DTPA renal dynamic imaging showed normal function or function slightly damaged on the contralateral kidney, the affected kidney received nephrectomy, others accepted expectant treatments and mostly with good recovery. Conclusion: ~(99m)Tc-DTPA renal dynamic imaging is an ideal method to assess preoperative renal function especially the single renal function in IVP detection failed patients. It is a simple, noninvasive, with high-sensitivity and repeatability.