Abstract:

Purpose

Trans-abdominal ultrasonography (US) is capable of determining size, shape, thickness, and diameter of uterus, cervix and disease at cervix or parametria. To assess the potential value of US for image-guided cervical cancer brachytherapy, we compared US-findings relevant for brachytherapy to the corresponding findings obtained from MR imaging.

Materials and methods

Twenty patients with biopsy proven cervical cancer undergoing definitive radiotherapy with/without concomitant Cisplatin chemotherapy and suitable for brachytherapy were invited to participate in this study. US and MR were performed in a similar reproducible patient positioning after intracavitary application. US mid-sagittal and axial image at the level of external cervical os was acquired. Reference points D1 to D9 and distances were identified with respect to central tandem and flange, to delineate cervix, central disease, and external surface of the uterus.

Results

Thirty-two applications using CT/MR compatible applicators were evaluable. The D1 and D3 reference distances which represent anterior surface had a strong correlation with R = 0.92 and 0.94 (p < 0.01). The D2 and D4 reference distances in contrast, which represent the posterior surface had a moderate (D2) and a strong (D4) correlation with R = 0.63 and 0.82 (p < 0.01). Of all, D2 reference distance showed the least correlation of MR and US. The D5 reference distance representing the fundal thickness from tandem tip had a correlation of 0.98. The reference distances for D6, D7, D8, and D9 had a correlation of 0.94, 0.82, 0.96, and 0.93, respectively.

Conclusions

Our study evaluating the use of US, suggests a reasonably strong correlation with MR in delineating uterus, cervix, and central disease for 3D conformal intracavitary brachytherapy planning.