摘    要:目的:评价全自动血培养仪BacT/Alert 240的临床应用情况,方法:回顾性分析BacT/Alert240全自动血培养系统检测7124份标本的阳性率,阳性检出时间,细菌种类以及假阳性率,假阴性率和污染率,结果:7124份血培养分离到804株微生物,其中细菌764株,阳性率11.5%,最快阳性检出时间2小时,24小时内检出的阳性占69.9%,48小时内占87.3%,72小时内占91.3%,804株细菌分布于24个属,假阳性率4.9%,假阴性率0.4%,污染率0.3%,结论:BacT/Alert 240全自动血培养仪提高了血培养的阳性率,缩短了阳性检出时间,检出细菌种类多尤其是苛养菌阳性率增加,减少污染机会,而且操作简便,结果快速,准确。

关 键 词:全自动血培养仪  血培养  细菌  临床应用
文章编号:1002-0179(2002)03-0366-03
修稿时间:2001年9月10日

Clinical Application and Evaluation of BacT/Alert 240 Automated Blood Culture System
TAO Chuan-min,WEN Xiao-bo,KUANG Yu,et al..Clinical Application and Evaluation of BacT/Alert 240 Automated Blood Culture System[J].West China Medical Journal,2002,17(3):366-368.
Authors:TAO Chuan-min  WEN Xiao-bo  KUANG Yu  
Abstract:Objective:To evaluate the value of automated blood culture system(BacT/Alert 240).Methods:A total of 7124 blood samples were detected by BacT/Alert 240 automated blood culture system.Positive rate,time to positive,the types of microorganisms recovered,false positive rate,false negative rate were analyzed retrospectively.Results:804 strains were isolated,positive rate was 11.5%,the shortest time to positive was 2h,the cumulative positive rates were 69.9% within 24h,87.3% within 48h,and 91.3% within 72h.There were 24 genera of microorganisms recovered.False positive rate was 4.9%,and false negative rate was 0.4%,and contaminative rate was 0.3%.Conclusion:The positive detection rate has been raised,the detection time to positive reduced,the genus of microorganisms increased and the chance of contamination decreased by using BacT/Alert 240 automated blood culture system.
Keywords:automated blood culture system  blood culture  microorganism
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号