首页 | 本学科首页   官方微博 | 高级检索  
检索        


Fetal dose estimates and the ICRP abdominal dose limit for occupational exposure of pregnant staff to technetium-99m and iodine-131 patients
Authors:P J Mountford  H R Steele
Institution:(1) Department of Nuclear Medicine, Queen Elizabeth Hospital, B15 2TH Edgbaston, Birmingham, UK;(2) Present address: Department of Biomedical Engineering and Medical Physics, North Staffordshire Hospital, Thornburrow Drive, Hartshill, ST4 7QB Stoke-on-Trent, Staffordshire, UK
Abstract:The International Commission on Radiological Protection has recently recommended a supplementary dose limit of 2 mSv to the abdominal surface of a pregnant member of staff in order to provide protection to her fetus comparable to that in members of the public, whose annual limit is recommended to be 1 mSv. In order to determine whether this apparent attenuation factor of 50% is appropriate for nursing and imaging staff exposed to nuclear medicine patients, estimates were made of the ratios of the maternal abdominal surface to fetal dose appropriately weighted for time, distance and dose rate. Thermoluminescent dosimeter (TLD) measurements were made at various depths in an anthropomorphic phantom irradiated at different distances by a distributed source of either technetium-99m or iodine-131 in order to determine the corresponding attenuation factors at the average fetal midline depth. Dose estimates were based on these factors and on published values of dose rate and exposure times for nursing and imaging staff at these distances from the patient. Fetal doses to nursing staff caring for an adult99mTc patient were estimated to vary from 86 mgrSv to 1.6 mgrSv, with the corresponding ratio of the abdominal surface to fetal dose varying from about 1.8:1 to 1.5:1 as the patient became less dependent on nursing care and the mean distance from the patient increased. Fetal doses to imaging staff varied from 1.12 mgrSv to 0.17 mgrSv for three types of99mTc scan, but the ratio only varied from 1.4:1 to 1.3:1. Fetal doses to imaging staff were estimated to be 6.7 mgrSv and 9.0 mgrSv for a whole-body scan of a thyroid cancer patient after 1311 ablation and therapy respectively, and the ratio was 1.3:1 for both types of scan. It was concluded that for a pregnant ward nurse or imaging technologist exposed to an adult or paediatric patient administered99mTc or131I, a dose limit of 1.3 mSv to the maternal abdominal surface will restrict their fetal dose to 1 mSv. A pregnant imaging technologist should perform no more than six adult99mTc studies or one131I whole-body scan per day, and may have to wear a more sensitive personal dosimeter than a film badge.
Keywords:Fetus  Dose  Limit  Technetium-99m  Iodine-131
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号