首页 | 本学科首页   官方微博 | 高级检索  
     


Cerebral cortical oxygenation: a pilot study
Authors:Gracias Vicente H  Guillamondegui Oscar D  Stiefel Michael F  Wilensky Eileen M  Bloom Stephanie  Gupta Rajan  Pryor John P  Reilly Patrick M  Leroux Peter D  Schwab C William
Affiliation:Department of Surgery, Division of Traumatology and Surgical Critical Care, University of Pennsylvania School of Medicine, 3440 Market Street, First Floor, Philadelphia, PA 19104, USA. graciasv@uphs.upenn.edu
Abstract:BACKGROUND: Cerebral hypoxia (cerebral cortical oxygenation [Pbro2] < 20 mm Hg) monitored by direct measurement has been shown in animal and small clinical studies to be associated with poor outcome. We present our preliminary results observing Pbro2 in patients with traumatic brain injury (TBI). METHODS: A prospective observational cohort study was performed. Institutional review board approval was obtained. All patients with TBI who required measurement of intracranial pressure (ICP), cerebral perfusion pressure (CPP), and Pbro2 because of a Glasgow Coma Scale score < 8 were enrolled. Data sets (ICP, CPP, Pbro2, positive end-expiratory pressure (PEEP), Pao2, and Paco2) were recorded during routine manipulation. Episodes of cerebral hypoxia were compared with episodes without. Results are displayed as mean +/- SEM; t test, chi2, and Fisher's exact test were used to answer questions of interest. RESULTS: One hundred eighty-one data sets were abstracted from 20 patients. Thirty-five episodes of regional cerebral hypoxia were identified in 14 patients. Compared with episodes of acceptable cerebral oxygenation, episodes of cerebral hypoxia were noted to be associated with a significantly lower mean Pao2 (144 +/- 14 vs. 165 +/- 8; p < 0.01) and higher mean PEEP (8.8 +/- 0.7 vs. 7.1 +/- 0.3; p < 0.01). Mean ICP and CPP measurements were similar between groups. In a univariate analysis, cerebral hypoxic episodes were associated with Pao2 < or = 100 mm Hg (p < 0.01) and PEEP > 5 cm H2O (p < 0.01), but not ICP > 20 mm Hg, CPP < or = 65 mm Hg, or Pac2 < or = 35 mm Hg. CONCLUSION: Cerebral oxymetry is confirmed safe in the patient with multiple injuries with TBI. Occult cerebral hypoxia is present in the traumatic brain injured patient despite normal traditional measurements of cerebral perfusion. Further research is necessary to determine whether management protocols aimed at the prevention of cerebral cortical hypoxia will affect outcome.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号