首页 | 本学科首页   官方微博 | 高级检索  
检索        

LPYP20压迫止血器和Medplus桡动脉止血带在经皮冠状动脉介入治疗后的止血效果对比
引用本文:赖浚兴,高伟栋,张学芳,林如明,彭宇程,张高星.LPYP20压迫止血器和Medplus桡动脉止血带在经皮冠状动脉介入治疗后的止血效果对比[J].岭南心血管病杂志,2010,16(5):394-396.
作者姓名:赖浚兴  高伟栋  张学芳  林如明  彭宇程  张高星
作者单位:江门市中心医院心内科,广东江门,529071
摘    要:目的比较LPYP20压迫止血器和Medplus桡动脉止血带在经皮冠状动脉介入治疗后桡动脉止血中的安全性、有效性及优缺点。方法经桡动脉行经皮冠状动脉介入治疗的患者116例,电脑数字随机法分成两组,其中64例采用LPYP20压迫止血器,52例采用Medplus桡动脉止血带。观察两组术后止血情况、桡动脉闭塞及局部并发症情况并进行对比。结果两组术后均能成功止血。两组在出血及桡动脉闭塞方面比较,差异无统计学意义(P0.05);在包扎远端肿胀、麻木、皮肤破损方面,Medplus桡动脉止血带优于LPYP20压迫止血器17.3%(9/52)vs.35.9%(23/64),P0.05;13.5%(7/52)vs.32.8%(21/64),P0.05;1.9%(1/52)vs.12.5%(8/64),P0.05]。结论两种压迫器均能成功达到止血目的 ,但Medplus桡动脉止血带对周围组织压迫更少,对皮肤损伤更小。

关 键 词:血管成形术,经腔,经皮冠状动脉  出血  桡动脉  并发症  LPYP20压迫止血器  Medplus桡动脉止血带

Comparison of LPYP20 compressor and Medplus radial artery tourniquet in radial percutaenous coronary intervention
LAI Jun-xing,GAO Wei-dong,ZHANG Xue-fang,LIN Ru-ming,PENG Yu-cheng,ZHANG Gao-xing.Comparison of LPYP20 compressor and Medplus radial artery tourniquet in radial percutaenous coronary intervention[J].South China Journal of Cardiovascular Diseases,2010,16(5):394-396.
Authors:LAI Jun-xing  GAO Wei-dong  ZHANG Xue-fang  LIN Ru-ming  PENG Yu-cheng  ZHANG Gao-xing
Institution:(Department of Cardiology,The Affiliated Jiangmen Hospital of Sun Yat-sen University,Jiangmen Guangdong 529071, China)
Abstract:Objectives To compare the safety, validity and superiority between LPYP20 radial artery compressor and Medplus radial artery tourniquet in percutaneous transluminal coronary angioplasty. Methods We randomly divided 116 patients undergoing percutaneous transluminal coronary angioplasty into two groups. Sixty four patients were included in LPYP20 group,and 52 in Medplus group. We compared the capacity of hemostasia and complications between the two groups. Results The immediate success rate of the 2 groups were 100%. There was no significant difference on hemorrhage and radial occlusion between the 2 groups (P〉0.05). There were significant differences in distal swelling, numbness and skin injuries between the 2 groups 17.3% (9/52) vs. 35.9% (23/64),P〈0.05; 13.5% (7/52) vs. 32.8% (21/64),P〈0.05; 1.9% (1/52) vs. 12.5% (8/64),P〈0.05]. Conclusions Two kinds of radial artery compressor are safe and effective in patients with the transradial approach, and the Medplus radial artery tourniquet is better because of smaller area compression and less skin injuries.
Keywords:percutaneous transluminal coronary angioplasty  bleeding  radial artery  complication  LPYP20 radial artery compressor  Medplus radial artery tourniquet
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号