首页 | 本学科首页   官方微博 | 高级检索  
     

多所医院医务人员医用防护口罩适合性研究
引用本文:胡美华,贾会学,姚希,孙昕霙,闵鹤葳,邓明卓,卢联合,李杰,宋丽红,路简羽,宋雪梅,高航,李六亿. 多所医院医务人员医用防护口罩适合性研究[J]. 中国感染控制杂志, 2022, 21(1): 1-7. DOI: 10.12138/j.issn.1671-9638.20222223
作者姓名:胡美华  贾会学  姚希  孙昕霙  闵鹤葳  邓明卓  卢联合  李杰  宋丽红  路简羽  宋雪梅  高航  李六亿
作者单位:1. 北京大学第一医院感染管理-疾病预防控制处, 北京 100034;2. 北京大学公共卫生学院社会医学与健康教育系, 北京 100191;3. 首都医科大学附属北京友谊医院, 北京 100050;4. 北京地坛医院感染管理科, 北京 100015;5. 首都医科大学附属复兴医院医院感染与疾病预防控制处, 北京 100038;6. 北京市密云区医院感控科, 北京 101599;7. 北京市第二医院院感科, 北京 100031
基金项目:首都卫生发展科研项目(首发2021-1G-4071)。
摘    要:目的 通过定量适合性测试,描述医用防护口罩的适合现状以及探索适合性测试的影响因素.方法 通过分层抽样选取6所不同级别、性质的医院中不同呼吸道传染病暴露风险部门,即低风险(普通病区)、中风险(如急诊、呼吸科门诊)、高风险(发热门诊、核酸采样点、感控处)的工作人员,包括医生、护士、医技、工勤人员,对两个品牌的拱形和折叠形口...

关 键 词:医务人员  医用防护口罩  口罩  适合性试验

Fit testing of respirators for health care workers in several hospitals
HU Mei-hua,JIA Hui-xue,YAO Xi,SUN Xin-ying,MIN He-wei,DENG Ming-zhuo,LU Lian-he,LI Jie,SONG Li-hong,LU Jian-yu,SONG Xue-mei,GAO Hang,LI Liu-yi. Fit testing of respirators for health care workers in several hospitals[J]. Chinese Journal of Infection Control, 2022, 21(1): 1-7. DOI: 10.12138/j.issn.1671-9638.20222223
Authors:HU Mei-hua  JIA Hui-xue  YAO Xi  SUN Xin-ying  MIN He-wei  DENG Ming-zhuo  LU Lian-he  LI Jie  SONG Li-hong  LU Jian-yu  SONG Xue-mei  GAO Hang  LI Liu-yi
Affiliation:(Department of Infection Management-Disease Control and Prevention, Peking University First Hospital, Beijing 100034, China;Department of Social Medicine and Health Education, Peking University School of Public Health, Beijing 100191, China;Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China;Department of Infection Management, Beijing Ditan Hospital, Beijing 100015, China;Department of Healthcare-associated Infection Management and Disease Prevention and Control, Fuxing Hospital, Capital Medical University, Beijing 100038, China;Department of Infection Control, Beijing Miyun District Hospital, Beijing 101599, China;Department of Healthcare-associated Infection Management, Beijing Second Hospital, Beijing 100031, China)
Abstract:Objective To evaluate the fit status of respirators and influencing factors of fit status through quantitative fitting testing.Methods Departments with different respiratory infectious disease exposure risks in 6 hospitals of different levels and properties were selected by stratified sampling,that is,hospital staff with low risk(ge-neral ward),medium risk(such as emergency and respiratory outpatient),and high risk(fever clinic,nucleic acid sampling point as well as department of infection control),including doctors,nurses,medical technicians and servicers,arch and folding respirators of two brands were tested,quantitative tightness and fitness of respirators were tested by environmental aerosol condensation nuclear counter method.Results A total of 320 staffs were selected from 6 hospitals to conduct the testing,before the formal fit testing,through professional guidance,the overall passing rate of the quantitative tightness check was significantly improved from 27.50%to 57.73%compared with the self-adjustment of the tested personnel.The passing rates of the fit testing of different respirators were significantly different(χ2=561.51,P<0.001),with the lowest of 0.94%and the highest of 84.06%.After quantitative fit testing,when carrying out fit testing for standard movements,passing rates of arch A,folding A,arch B and folding B respirators were 50.00%,58.25%,66.67%and 85.67%respectively.Passing rates began to drop mainly after the left and right head swing.Conclusion Fit testing is a favorable tool to ensure the efficacy of respiratory protection,fit testing data should be fully utilized to provide suitable respirators for the staff.
Keywords:health care worker  respirator  mask  fit testing
本文献已被 维普 等数据库收录!
点击此处可从《中国感染控制杂志》浏览原始摘要信息
点击此处可从《中国感染控制杂志》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号