首页 | 本学科首页   官方微博 | 高级检索  
检索        

厢式电梯通风方式对咳嗽飞沫核扩散的影响及风险分析
引用本文:梅丹,王晨霞,李佳倩,幸福堂.厢式电梯通风方式对咳嗽飞沫核扩散的影响及风险分析[J].中国感染控制杂志,2022,21(1):8-14.
作者姓名:梅丹  王晨霞  李佳倩  幸福堂
作者单位:武汉科技大学资源与环境工程学院, 湖北 武汉 430081
基金项目:湖北省中央引导地方科技发展专项(2020ZYYD019)。
摘    要:目的 在新型冠状病毒肺炎疫情背景下,探讨不同通风方式对轿厢式电梯内人员咳嗽飞沫核扩散的影响.方法 基于计算流体力学气固两相流原理,采用Realizable k-ε紊流模型和颗粒轨道模型研究轿厢式电梯内人员咳嗽产生的飞沫核在10 s内的扩散过程,比较三种电梯顶部送风(后部、两侧以及四角通风方式)下的气流速度变化、飞沫核扩...

关 键 词:通风  电梯  咳嗽飞沫核  气溶胶  扩散  风险分析  新型冠状病毒肺炎

Impact and risk of ventilation modes of elevator on the diffusion of cough droplet nuclei
MEI Dan,WANG Chen-xia,LI Jia-qian,XING Fu-tang.Impact and risk of ventilation modes of elevator on the diffusion of cough droplet nuclei[J].Chinese Journal of Infection Control,2022,21(1):8-14.
Authors:MEI Dan  WANG Chen-xia  LI Jia-qian  XING Fu-tang
Institution:School of Resource and Environmental Engineering, Wuhan University of Science and Technology, Wuhan 430081, China
Abstract:Objective To evaluate the effect of different ventilation modes on the diffusion of person’s cough droplet nuclei in the elevator under the background of coronavirus disease 2019 epidemic.Methods Based on the computational fluid dynamics(CFD)gas-solid two-phase flow,Realizable K-εturbulence model and particle trajectory model were used to study the diffusion process of droplet nuclei generated by person’s cough in the elevator within 10 seconds,airflow velocity variation,droplet nuclei diffusion characteristics and concentration distribution of three kinds of ventilation at elevator top(the rear,both sides and four corners ventilation)were compared,risk on person was analyzed.Results Within 10 seconds,the number of airflow velocity vortex gradually decreased under the condition of ventilation at the rear and both sides,while increased when ventilation was at the four corners;droplet nuclei moved with the airflow in an inverted“S”shape trajectory when ventilation was at the rear,droplet nuclei moved up and down with the airflow when ventilation was at both sides,droplet nuclei presented a“C”shape trajectory when ventilation was at four corner.After 10 seconds,the increase of ventilation could quickly reduce the droplet nuclei concentration by 90%.Conclusion The opposite side of the droplet releaser is the high-risk area of contacting with the bacteria-carrying droplet nuclei.Although four corner ventilation can quickly dilute the overall droplet nuclear concentration,risk of infection can be increased if there is droplet releaser who is at the oblique opposite.Ventilation site should also be considered when ventilation volume increases,so as to reduce the risk of personnel infection.
Keywords:ventilation  elevator  cough droplet nuclei  aerosol  diffusion  risk analysis  coronavirus disease 2019
本文献已被 维普 等数据库收录!
点击此处可从《中国感染控制杂志》浏览原始摘要信息
点击此处可从《中国感染控制杂志》下载免费的PDF全文