Evaluation of posttransplantation soluble CD30 for diagnosis of acute renal allograft rejection |
| |
Authors: | Pelzl Steffen Opelz Gerhard Daniel Volker Wiesel Manfred Süsal Caner |
| |
Institution: | Department of Transplantation Immunology, Institute of Immunology, University of Heidelberg, Heidelberg, Germany. |
| |
Abstract: | BACKGROUND: Posttransplantation measurement of soluble CD30 (sCD30) may be useful for identifying kidney graft recipients at risk of impending graft rejection in the early posttransplantation period. METHODS: We measured plasma sCD30 levels and evaluated the levels in relation to the diagnosis of rejection. RESULTS: Receiver operating characteristic curves demonstrated that on posttransplantation days 3 to 5, sCD30 allowed a differentiation of recipients who subsequently developed acute allograft rejection (n=25) from recipients with an uncomplicated course (n=20, P<0.0001) (area under the receiver operating characteristic curve 0.96, specificity 100%, sensitivity 88%) and recipients with acute tubular necrosis in the absence of rejection (n=11, P=0.001) (area under the receiver operating characteristic curve 0.85, specificity 91%, sensitivity 72%). CONCLUSIONS: sCD30 measured on posttransplantation days 3 to 5 offers a noninvasive means for differentiating patients with impending acute allograft rejection from patients with an uncomplicated course or with acute tubular necrosis. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|