Liver fibrosis: non-invasive assessment with MR elastography |
| |
Authors: | Huwart Laurent Peeters Frank Sinkus Ralph Annet Laurence Salameh Najat ter Beek Leon C Horsmans Yves Van Beers Bernard E |
| |
Affiliation: | Diagnostic Radiology Unit, Université Catholique de Louvain, Brussels, Belgium. |
| |
Abstract: | The aim of this study was to assess the feasibility of using non-invasive MR elastography for determining the stage of liver fibrosis. Twenty-five consecutive patients who had liver biopsy for suspicion of chronic liver disease were included in the study. The stage of fibrosis on the biopsies was assessed according to the METAVIR scoring system from F0, no fibrosis, to F4, cirrhosis. MR elastography was performed by transmitting low-frequency (65 Hz) mechanical waves into the liver with a transducer placed at the back of the patients. The MR pulse sequence was a motion-sensitized spin-echo sequence, phase-locked to the mechanical excitation. The phase maps were processed to obtain shear elasticity and shear viscosity maps. The mean hepatic shear elasticity increased with increasing stage of fibrosis. The mean elasticity was 2.24 +/- 0.23 kPa in the 11 patients without substantial fibrosis (F0-F1 grades), 2.56 +/- 0.24 kPa in the four patients with substantial fibrosis (F2-F3) and 4.68 +/- 1.61 kPa in the 10 patients with cirrhosis (F4). The differences between groups were statistically significant (p
|
| |
Keywords: | elastography liver liver fibrosis |