摘    要:目的:评估A超测量不同眼轴长度区间的眼轴长度(AL)和中央前房深度(ACD)的可重复性,并与IOL Master检查结果比较,为临床实践提供依据.方法:选取白内障患者170例257眼,术前分别行IOL Master和A超检查,其中每只受试眼IOL Master自动测量5次,A超测量3次,分别取平均值.按A超测得的AL分为5组:A组:2129mm(21眼).Cronbach's Alpha系数及组内相关系数(ICC)评估A超测量AL和ACD的可重复性.配对样本t检验和Pearson相关系数分析各组中A超和IOL Master测量的AL和ACD的差异性和相关性.Bland-Altman分析A超和IOL Master测量的AL和ACD的一致性.结果:A超测量的AL和ACD的Cronbach's Alpha系数和ICC均大于0.98.A、B、C、D、E组中, A超测量的AL与IOL Master测量的AL差值分别为-0.11±0.08、-0.15±0.10、-0.19±0.15、-0.29±0.16、-0.45±0.29mm,差异均有统计学意义(均P<0.01);ACD差值分别为-0.10±0.16、-0.06±0.13、-0.06±0.13、-0.19±0.10、-0.18±0.21mm,差异均有统计学意义(均P<0.01).A、B、C、D、E组中,A超和IOL Master测量的AL和ACD均具有很好的相关性(均r >0.89,P<0.01).结论:A超测量白内障患者的AL和ACD具有很好的可重复性,且数值均比IOL Master小;其中不同眼轴长度的差异,随着眼轴的增长而增大.

关 键 词:眼轴长度  前房深度  A超  IOL Master生物测量仪
收稿时间:2017-04-04
修稿时间:2017-07-31

Comparison of axial length and anterior chamber depth obtained by A scan ultrasonography and IOL Master in different axial length groups
Feng-Miao Zhuang,Qiu-Yi Xiao and Yan-Jun Hua. Comparison of axial length and anterior chamber depth obtained by A scan ultrasonography and IOL Master in different axial length groups[J]. International Eye Science, 2017, 17(9): 1650-1654. DOI: 10.3980/j.issn.1672-5123.2017.9.11
Authors:Feng-Miao Zhuang  Qiu-Yi Xiao  Yan-Jun Hua
Affiliation:Department of Special Examine, the Eye Hospital of Wenzhou Medical University, Wenzhou 325000, Zhejiang Province, China,Department of Ophthalmology, the Sixth People''s Hospital Affiliated to Shanghai Jiao Tong University, Shanghai 200233, China and Department of Ophthalmology, the Sixth People''s Hospital Affiliated to Shanghai Jiao Tong University, Shanghai 200233, China
Abstract:AIM:To evaluate the repeatability of axial length (AL) and anterior chamber depth (ACD) obtained by A scan ultrasonography, and to compare AL and ACD obtained by A scan with those obtained by IOL Master.METHODS:Two hundred and fifty-seven cataract eyes of 170 patients were included.IOL Master and A scan were performed for each eye.Five measurements of IOL Master and 3 measurements of A scan were obtained.All the tested eyes were divided into 5 groups according to AL obtained by A scan:Group A (2129mm, 21 eyes).Cronbach's Alpha coefficient and intraclass correlation coefficient (ICC) were applied to evaluate the repeatability of AL and ACD obtained by A scan.Paired t test and Pearson correlation coefficient were used to analyze the differences and correlations of AL and ACD obtained by the 2 devices, respectively.Bland-Altman plots were presented to analyze the agreements of AL and ACD obtained by the 2 devices.RESULTS:All the Cronbach's Alpha and ICCs of AL and ACD values were more than 0.98.The differences of AL values between A scan and IOL Master were-0.11±0.08mm in Group A,-0.15±0.10mm in Group B,-0.19±0.15 mm in Group C,-0.29±0.16mm in Group D and-0.45±0.29mm in Group E, respectively (all P<0.01).The differences of ACD values between A scan and IOL Master were-0.10±0.16mm in Group A,-0.06±0.13mm in Group B,-0.06±0.13mm in Group C,-0.19±0.10mm in Group D,-0.18±0.21mm in Group E, respectively (all P<0.01).In all groups, the AL and ACD values obtained by A scan and IOL Master presented good correlations (all r>0.89, all P<0.01).CONCLUSION:The AL and ACD values in cataract eyes obtained by A scan were repeatable.The AL and ACD values obtained by A scan were smaller than those obtained by IOL Master.With the increase of AL values, the differences of AL values between A scan and IOL Master increased.
Keywords:axial length   anterior chamber depth   A scan ultrasonography   IOL Master