首页 | 本学科首页   官方微博 | 高级检索  
检索        

离体猪肝微波消融灶的弹性变化及其病理意义
引用本文:章建全,刁宗平,卢峰,盛建国,何金.离体猪肝微波消融灶的弹性变化及其病理意义[J].中华超声影像学杂志,2011,20(1).
作者姓名:章建全  刁宗平  卢峰  盛建国  何金
作者单位:1. 第二军医大学附属长征医院超声诊疗科,上海,200003
2. 第二军医大学附属长征医院病理科,上海,200003
基金项目:第二军医大学附属长征医院"三重三优"学科和人才建设专项基金
摘    要:目的 探讨微波消融致离体猪肝弹性改变及其与肝组织坏死程度之间的对应关系.方法 以离体猪肝为消融模型,利用弹性超声的色彩显示和应变率比值定量检测对消融前后靶区的弹性进行对照研究,同步观察靶区的组织学变化.结果 随微波功率增大和消融时间加长,消融区的弹性显著降低,硬度增大,同时细胞坏死和碳化程度加重,并以微波功率的影响为著.结论 弹性超声检查提示微波消融令离体猪肝迅速变硬,可从硬变程度推断凝固坏死的程度.
Abstract:
Objective To investigate the elasticity reduction of liver tissue due to microwave ablation and the relevance to the histographic damages. Methods An experimental study using fresh porcine liver was designed. Elasto-ultrasonography scanning both in color display and strain ratio calculations was conducted before and 5 min after microwave ablation ( 2450 MHz) in manner of antenna insertion under ultrasound guidance to determine the alterations of the liver elasticity, in correspondence with the histopathologic assessment of each ROI. Results Elasto-ultrasonography showed a significant elasticity reduction and hardness augment of the targeted liver tissue and the corresponding histopathology revealed increases in the amount of massive coagulative necrosis and coking of liver cells after microwave irradiation,in proportional to the applied field power and working time. Conclusions Elasto-ultrasonography helps to demonstrate microwave-induced lesion in porcine liver got rapidly hardened. It is possible to estimate the tissue necrosis to the changing of tissue hardening.

关 键 词:超声检查  微波/治疗应用  

Elastographic characterization of microwave-induced lesions in porcine liver
ZHANG Jian-quan,DIAO Zong-ping,LU Feng,SHENG Jian-guo,HE Jin.Elastographic characterization of microwave-induced lesions in porcine liver[J].Chinese Journal of Ultrasonography,2011,20(1).
Authors:ZHANG Jian-quan  DIAO Zong-ping  LU Feng  SHENG Jian-guo  HE Jin
Abstract:Objective To investigate the elasticity reduction of liver tissue due to microwave ablation and the relevance to the histographic damages. Methods An experimental study using fresh porcine liver was designed. Elasto-ultrasonography scanning both in color display and strain ratio calculations was conducted before and 5 min after microwave ablation ( 2450 MHz) in manner of antenna insertion under ultrasound guidance to determine the alterations of the liver elasticity, in correspondence with the histopathologic assessment of each ROI. Results Elasto-ultrasonography showed a significant elasticity reduction and hardness augment of the targeted liver tissue and the corresponding histopathology revealed increases in the amount of massive coagulative necrosis and coking of liver cells after microwave irradiation,in proportional to the applied field power and working time. Conclusions Elasto-ultrasonography helps to demonstrate microwave-induced lesion in porcine liver got rapidly hardened. It is possible to estimate the tissue necrosis to the changing of tissue hardening.
Keywords:Ultrasonography  Microwaves/therapeutic use  Liver
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号