Transcranial contrast diminution imaging of the human brain: a pilot study in healthy volunteers |
| |
Authors: | Meyer Karsten Seidel Günter |
| |
Affiliation: | Department of Neurology, University Hospital Lübeck, Ratzeburger Allee 160, D-23538 Lübeck, Germany. |
| |
Abstract: | Analysis of contrast diminution kinetics after bubble destruction is a new aspect in harmonic imaging. The purpose of this study was to investigate this approach to human cerebral perfusion. A total of 12 healthy volunteers were investigated transtemporally (Philips SONOS 5500, S4-probe, 1.8 to 3.6 MHz, 10 cm) at two ultrasound (US) contrast agent (UCA) infusion rates (0.5 and 1.0 mL/min of Optison). After achieving a steady-state, a set of 12 US pulses (6.67 Hz, MI 1.6) was applied. Time-intensity plots of three regions-of-interest (ROIs) (thalamus, white matter and cortex) were analyzed, using an exponential curve fit (I((t)) = I(0)e(-betat) + B). A total of 20 of 20 successful investigations showed a signal decrease after pulsed US application. In all cases, it was possible to generate exponential time-intensity curves. Half-life (T(1/2) = ln2/beta) and baseline intensity (B) showed a significant dependence on infusion rate (p = 0.01). At 1.0 mL/min, T(1/2) also depended on investigation depth (p = 0.01). It is possible to assess contrast diminution kinetics in human cerebral microcirculation. This new approach may provide additional information on cerebral perfusion within a short investigation time. |
| |
Keywords: | Ultrasonography Harmonic imaging Ultrasound contrast agents Microbubbles Cerebral perfusion |
本文献已被 ScienceDirect PubMed 等数据库收录! |
|