首页 | 本学科首页   官方微博 | 高级检索  
检索        


Myocardial single-photon emission computed tomographic imaging with technetium 99m tetrofosmin: Stress-rest imaging with same-day and separate-day rest imaging
Authors:Bangalore Sridhara  Heinz Sochor  Pierre Rigo  Simon Braat  Roland Itti  David Martinez-Duncker  Paul Cload  Avijit Lahiri
Institution:1. Northwick Park Hospital and Clinical Research Centre, Harrow, UK
2. University Hospital, Vienna, Austria
3. Centre Hospitalier Universiat, Liege, Belgium
4. Academisch Ziekenhuis, Maastricht, The Netherlands
5. Hospital Neuro-Cardiologique, Lyon, France
6. Amersham International plc, Amersham, UK
Abstract:

Background

Technetium 99m tetrofosmin is a new ethylene diphosphine ligand for myocardial perfusion imaging and has unique properties. We have compared stress-rest single-photon emission computed tomographic (SPECT) imaging with99mTc tetrofosmin with same-day and separate-day rest imaging to detect myocardial perfusion defects.

Methods and Results

Myocardial SPECT imaging was performed in 22 patients with coronary artery disease who had undergone planar thallium 201 imaging and coronary angiography. Single-day (stress-rest) and separate-day rest99mTc tetrofosmin SPECT protocols were compared in the same patient. Images were assessed by a blinded panel to identify myocardial infarction, ischemia, or normal scans. Overall sensitivity for identification of patients with coronary artery disease was 86% (19/22) by both same-day stress-rest and separate-day rest protocols with99mTc tetrofosmin (p=NS). Of a total of 396 segments studied, 107 abnormal segments were identified at exercise and 76 and 81 at the same-day and separate-day rest tests, respectively (p=NS). Same-day stress-rest and separate-day rest99mTc tetrofosmin SPECT protocols were also useful for detecting individual coronary stenosis with a greater than 50% lesion: 80% of the left anterior descending, 93% of the right coronary, and 75% of the left circumflex coronary arteries were detected.

Conclusion

Excellent images were obtained with99mTc tetrofosmin during both stress and rest.99mTc tetrofosmin imaging with the same-day stress-rest and separate-day rest imaging protocols have similar diagnostic sensitivities for detection of coronary heart disease.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号