首页 | 本学科首页   官方微博 | 高级检索  
     


Percutaneous nitroglycerin absorption in rats.
Authors:S T Horhota  H L Fung
Abstract:Percutaneous nitroglycerin absorption was studied in shaved rats by monitoring unchanged plasma drug concentrations for up to 4 hr. Drug absorption from the neat liquid state or from an alcoholic solution was considerably poorer than that from a commercial ointment. This observation was unanticipated since the driving force for percutaneous drug absorption was assumed to be drug thermodynamics. Potential artifacts such as drug volatilization from the skin, reduction of surface area through droplet formation, and vehicle occlusion were investigated, but they did not appear to be responsible for the observed results. Two experimental aqueous nitroglycerin gels were prepared with polyethylene glycol 400. One gel contained just sufficient polyethylene glycol to solubilize the nitroglycerin; the other had excess polyethylene glycol to solubilize nitroglycerin far below saturation. Both gels gave extremely low plasma nitroglycerin levels. The composite data suggested that percutaneous nitroglycerin absorption is highly vehicle dependent and that this dependency cannot be explained by simple consideration of drug thermodynamic activity.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号