首页 | 本学科首页   官方微博 | 高级检索  
     


Encoding laboratory testing data: case studies of the national implementation of HHS requirements and related standards in five laboratories
Authors:Raja A Cholan  Gregory Pappas  Greg Rehwoldt  Andrew K Sills  Elizabeth D Korte  I Khalil Appleton  Natalie M Scott  Wendy S Rubinstein  Sara A Brenner  Riki Merrick  Wilbur C Hadden  Keith E Campbell  Michael S Waters
Affiliation:Deloitte Consulting LLP, Washington, District of Columbia, USA;Office of the National Coordinator for Health Information Technology, Washington, District of Columbia, USA;U.S. Food and Drug Administration, Silver Spring, Maryland, USA;U.S. Department of Health and Human Services, Silver Spring, Maryland, USA;Association for Public Health Laboratories, Silver Spring, Maryland, USA;University of Maryland, College Park, Maryland, USA;U.S. Department of Veterans Affairs, Bend, Oregon, USA
Abstract:ObjectiveAssess the effectiveness of providing Logical Observation Identifiers Names and Codes (LOINC®)-to-In Vitro Diagnostic (LIVD) coding specification, required by the United States Department of Health and Human Services for SARS-CoV-2 reporting, in medical center laboratories and utilize findings to inform future United States Food and Drug Administration policy on the use of real-world evidence in regulatory decisions.Materials and MethodsWe compared gaps and similarities between diagnostic test manufacturers’ recommended LOINC® codes and the LOINC® codes used in medical center laboratories for the same tests.ResultsFive medical centers and three test manufacturers extracted data from laboratory information systems (LIS) for prioritized tests of interest. The data submission ranged from 74 to 532 LOINC® codes per site. Three test manufacturers submitted 15 LIVD catalogs representing 26 distinct devices, 6956 tests, and 686 LOINC® codes. We identified mismatches in how medical centers use LOINC® to encode laboratory tests compared to how test manufacturers encode the same laboratory tests. Of 331 tests available in the LIVD files, 136 (41%) were represented by a mismatched LOINC® code by the medical centers (chi-square 45.0, 4 df, P < .0001).DiscussionThe five medical centers and three test manufacturers vary in how they organize, categorize, and store LIS catalog information. This variation impacts data quality and interoperability.ConclusionThe results of the study indicate that providing the LIVD mappings was not sufficient to support laboratory data interoperability. National implementation of LIVD and further efforts to promote laboratory interoperability will require a more comprehensive effort and continuing evaluation and quality control.
Keywords:health information interoperability   clinical laboratory information systems   public reporting of healthcare data   Logical Observation Identifiers Names and Codes
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号