比较PET/CT显像中肝脏18F-FDG摄取半定量分析方法
引用本文:张新超,边艳珠,国方娜,吴大勇,胡玉敬.比较PET/CT显像中肝脏18F-FDG摄取半定量分析方法[J].中国医学影像技术,2018,34(1):68-72.
作者姓名:张新超  边艳珠  国方娜  吴大勇  胡玉敬
作者单位:河北省人民医院核医学科, 河北 石家庄 050051,河北省人民医院核医学科, 河北 石家庄 050051,河北省人民医院核医学科, 河北 石家庄 050051,河北省人民医院核医学科, 河北 石家庄 050051,河北省人民医院核医学科, 河北 石家庄 050051
摘    要:目的 探讨PET/CT显像中影响肝脏18F-FDG摄取的因素,分析常规体质量(BM)、瘦体质量(LBM)及体表面积(BSA)校正最大标准化摄取值(SUVmax-B、SUVmax-L、SUVmax-S)的应用价值。方法 回顾性分析行18F-FDG PET/CT显像的67名健康受检者。测量肝脏SUVmax-B、SUVmax-L及SUVmax-S,分析年龄、空腹血糖水平、体质量指数(BMI)、肝脏CT值、性别、脂肪肝对上述参数的影响。结果 空腹血糖水平与肝脏SUVmax-B、SUVmax-L、SUVmax-S均呈正相关(r=0.329、0.336、0.353,P=0.012、0.010、0.007)。BMI与肝脏SUVmax-B (r=0.543,P<0.01)、SUVmax-L (r=0.328,P=0.07)呈正相关BMI与SUVmax-S无相关性(r=0.026,P=0.833)。受检者年龄、肝脏CT值与肝脏SUVmax-B、SUVmax-L、SUVmax-S均无相关性(P均>0.05)。男性肝脏SUVmax-B (t=2.608,P=0.011)、SUVmax-L (t=5.272,P<0.001)明显高于女性,男性与女性肝脏SUVmax-S无统计学差异(t=0.759,P=0.450)。脂肪肝受检者与非脂肪肝受检者肝脏SUVmax-B、SUVmax-L、SUVmax-S均无统计学差异(P=0.646、0.775、0.068)。结论 空腹血糖水平、BMI、性别是PET/CT显像中影响肝脏摄取18F-FDG的因素。BMI较大的受检者可采用SUVmax-L或SUVmax-S代替SUVmax-B,此外SUVmax-S可弥补性别间的差异,但校正技术无法减弱血糖水平对肝脏SUVmax的影响。

关 键 词:体层摄影术  发射型计算机  标准化摄取值  瘦体质量  体表面积  肝脏
收稿时间:2017/3/23 0:00:00
修稿时间:2017/10/19 0:00:00

Comparison on semi-quantitative analysis methods of liver 18F-FDG uptake in PET/CT imaging
ZHANG Xinchao,BIAN Yanzhu,GUO Fangn,WU Dayong and HU Yujing.Comparison on semi-quantitative analysis methods of liver 18F-FDG uptake in PET/CT imaging[J].Chinese Journal of Medical Imaging Technology,2018,34(1):68-72.
Authors:ZHANG Xinchao  BIAN Yanzhu  GUO Fangn  WU Dayong and HU Yujing
Institution:Department of Nuclear Medicine, Hebei General Hospital, Shijiazhuang 050051, China,Department of Nuclear Medicine, Hebei General Hospital, Shijiazhuang 050051, China,Department of Nuclear Medicine, Hebei General Hospital, Shijiazhuang 050051, China,Department of Nuclear Medicine, Hebei General Hospital, Shijiazhuang 050051, China and Department of Nuclear Medicine, Hebei General Hospital, Shijiazhuang 050051, China
Abstract:Objective To explore the impact factors of liver uptake of 18F-FDG in PET/CT imaging, and to preliminary analyze the application of maximum standardized uptake values corrected by conventional body mass, lean body mass and body surface area (SUVmax-B, SUVmax-L, SUVmax-S).Methods A retrospective analysis was performed on 67 healthy subjects who underwent 18F-FDG PET/CT. SUVmax-B, SUVmax-L and SUVmax-S were measured, and the impact of age, levels of fasting blood glucose, body mass index (BMI), CT value of liver, gender and the fatty liver on SUVmax-B, SUVmax-L and SUVmax-S were analyzed.Results The liver SUVmax-B, SUVmax-L, SUVmax-S were positively correlated with the levels of fasting blood glucose (r=0.329, 0.336, 0.353, P=0.012, 0.010, 0.007). There was a positive correlation between BMI and SUVmax-B (r=0.543, P<0.01), SUV-L (r=0.328, P=0.007), while BMI value had no correlation with SUVmax-S (r=0.026, P=0.833). There was no correlation between age, CT value of the liver nor SUVmax-B, SUVmax-L and SUVmax-S (all P>0.05). The liver SUVmax-B (t=2.608, P=0.011) and SUVmax-L (t=5.272, P=0.001) of male were significantly higher than those of female, while there was no difference between male''s and female''s liver SUVmax-S and liver SUVmax-S (t=0.759, P=0.450). There was no difference in SUVmax-B, SUVmax-L nor SUVmax-S between fatty liver subjects and non-fatty liver subjects (P=0.646, 0.775, 0.068).Conclusion The fasting blood glucose level, BMI and sex are the impact factors of liver uptake of 18F-FDG in PET/CT imaging. SUVmax-B can be replaced by SUVmax-L or SUVmax-S for larger BMI subjects, while SUVmax-S can make up differences between different genders. However, correction techniques can not weaken the impact of blood glucose level on SUVmax value of liver.
Keywords:Tomography  emission-computed  Standard uptake value  Lean body mass  Body surface area  Liver