Endosonography during endoscopic mucosal resection to enhance its safety
Authors:Y. Izumi  H. Inoue  T. Kawano  M. Tani  M. Tada  S. Okabe  K. Takeshita  M. Endo
Affiliation:First Department of Surgery, Tokyo Medical and Dental University, 5-45, Yushima 1-chome, Bunkyo-ku, Tokyo, Japan.
Abstract:BACKGROUND: We have performed endoscopic mucosal resection of the esophagus (172 cases), stomach (102 cases), and colon (28 cases) using a transparent plastic cap. Because the lesion-bearing mucosa is suctioned up inside the cap under endoscopic suction, the mucosa should be dissected sufficiently from the proper muscle layer to prevent perforation. METHODS: To avert the risk of perforation, we introduced endosonographic assessment of submucosal dissection (47 cases). In all cases, just keeping the ultrasonic probe on the surface of the mucosa allowed us to evaluate whether the mucosal lesion was lifted up sufficiently from the proper muscle layer after local saline injection. RESULTS: It was possible to confirm that the muscle layer was kept outside the strangulating snare by the same procedure (32 of 37 cases, 86.5%). CONCLUSIONS: We experienced five muscular resections in cases without the ultrasonic probe and no muscular resection with the ultrasonic probe. Thus we recommend endosonographic assessment during endoscopic mucosal resection to enhance its safety.