首页 | 本学科首页   官方微博 | 高级检索  
检索        


RELIABILITY OF TWO METHODS OF CLINICAL EXAMINATION OF THE FLEXIBILITY OF THE HIP ADDUCTOR MUSCLES
Authors:Antonio Cejudo  Francisco Ayala  Pilar Sainz De Baranda  Fernando Santonja
Institution:1.INACUA Sports Centre, Murcia, Spain.;2.Sports Research Centre, Miguel Hernández University of Elche, Alicante, Spain. ISEN University Formation, center affiliate to the University of Murcia;3.Faculty of Sport Sciences and Physical Activity, University of Murcia, Spain.;4.Faculty of Medicine, University of Murcia. Department of Traumatology, V. de la Arrixaca University Hospital, Murcia, Spain
Abstract:

Background

An inadequate level of flexibility of the adductor muscles is one of the most critical risk factors for chronic groin pain and strains. However, measurement methods of adductor muscle flexibility are not well defined.

Purpose

To determine the inter‐session reliability of the biarticular and monoarticular adductor muscle flexibility measures obtained from passive hip abduction with the knee flexed over the edge of the plinth test (PHA) and the passive hip abduction test at 90° of hip flexion (PHA90°).

Study design

Clinical Measurement Reliability study.

Methods

Fifty healthy recreational athletes participated in this study. All participants performed the PHA and PHA90° on four different occasions, with a two‐week interval between testing sessions. Reliability was examined through the change in the mean between consecutive pairs of testing sessions (ChM), standard error of measurement expressed in absolute values (SEM) and as a percentage of the mean score (%SEM), minimal detectable change at 95% confidence interval (MDC95), and intraclass correlation coefficients (ICC2,k).

Results

The findings showed negligible or trivial ChM values for the two adductor flexibility measures analyzed (<2°). Furthermore, the SEM and MDC95 were 2.1° and 5.9° and 2.2° and 6.2° for the measures obtained from the PHA and PHA90°, respectively, with %SEM scores lower than 5% and ICC scores higher than 0.90.

Conclusion

The findings from this study suggest that the adductor muscle flexibility measures analyzed have good to excellent inter‐session reliability in recreational athletes. Thus, clinicians can be 95% confident that an observed change between two measures larger than 5.9° and 6.2° for the flexibility measures obtained from the PHA and PHA90°, respectively, would indicate a real change in muscle flexibility.

Level of evidence

2
Keywords:Groin injury  muscle strain  physical therapy  range of motion  reproducibility