Measurement of T1 and T2 in the cervical spinal cord at 3 tesla |
| |
Authors: | Seth A Smith Richard A E Edden Jonathan A D Farrell Peter B Barker Peter C M Van Zijl |
| |
Affiliation: | Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD 21205, USA. smith@mri.jhu.edu |
| |
Abstract: | T(1) and T(2) were measured for white matter (WM) and gray matter (GM) in the human cervical spinal cord at 3T. T(1) values were calculated using an inversion-recovery (IR) and B(1)-corrected double flip angle gradient echo (GRE) and show significant differences (p = 0.002) between WM (IR = 876 +/- 27 ms, GRE = 838 +/- 54 ms) and GM (IR = 973 +/- 33 ms, GRE = 994 +/- 54 ms). IR showed significant difference between lateral and dorsal column WM (863 +/- 23 ms and 899 +/- 18 ms, respectively, p = 0.01) but GRE did not (p = 0.40). There was no significant difference (p = 0.31) in T(2) between WM (73 +/- 6 ms) and GM (76 +/- 3 ms) or between lateral and dorsal columns (lateral: 73 +/- 6 ms, dorsal: 72 +/- 7 ms, p = 0.59). WM relaxation times were similar to brain structures with very dense fiber packing (e.g., corpus callosum), while GM values resembled deep GM in brain. Optimized sequence parameters for maximal contrast between WM and GM, and between WM and cerebrospinal fluid (CSF) were derived. Since the spinal cord has rostral-caudal symmetry, we expect these findings to be applicable to the whole cord. |
| |
Keywords: | relaxation measurement spinal cord 3 Tesla T1 T2 |
|
|