首页 | 本学科首页   官方微博 | 高级检索  
     

圆锥角膜患者使用Rose K2软性角膜接触镜的临床表现
引用本文:Ihsan Yilmaz,Ferah Ozcelik,Gokhan Demir,Gonul Durusoy,Basak Saracoglu,Muhittin Taskapili. 圆锥角膜患者使用Rose K2软性角膜接触镜的临床表现[J]. 国际眼科杂志, 2017, 17(8): 1415-1418. DOI: 10.3980/j.issn.1672-5123.2017.8.06
作者姓名:Ihsan Yilmaz  Ferah Ozcelik  Gokhan Demir  Gonul Durusoy  Basak Saracoglu  Muhittin Taskapili
作者单位:土耳其,伊斯坦布尔34420,贝约格鲁眼科医疗与研究医院
摘    要:目的:评价圆锥角膜患者使用Rose K2软性角膜接触镜的舒适度及视觉表现.方法:横断面研究.50例患者(50眼)接受全面的眼科检查,包括屈光度、裸眼视力(UCVA)、最佳矫正视力(BCVA)、裂隙灯显微镜及眼底检查、泪膜破裂时间(BUT)、角膜地形图和对比敏感度.戴镜后,测量最佳戴镜矫正视力(BCLCVA)、对比敏感度及舒适度通过平均视觉模拟量(VAS)呈现.结果:患者平均年龄为26.2依6.0 (16 ~39) y.使用Rose K2软性角膜接触镜 UCVA,BCVA,和 BCLCVA 的平均logMAR值依次为0.61依0.37 (0.15 ~1.3),0.42依0.32 (0~1.3) 和0.18依0.20 (0 ~1.3).使用接触镜后视敏度显著提高(P<0.05),在明视和暗视条件下,对比敏感度数值明显增加(P<0.05).Rose K2软性角膜接触镜的视觉模拟量(VAS)值为8.02依1.64(5~10).结论:圆锥角膜患者使用Rose K2软性角膜接触镜能够改善视力,对比敏感度以及舒适度.

关 键 词:角膜接触镜  圆锥角膜患者  软性角膜接触镜
收稿时间:2016-01-31
修稿时间:2017-05-19

Clinical performance of Rose K2 soft contact lens for keratoconus
Ihsan Yilmaz,Ferah Ozcelik,Gokhan Demir,Gonul Durusoy,Basak Saracoglu and Muhittin Taskapili. Clinical performance of Rose K2 soft contact lens for keratoconus[J]. International Eye Science, 2017, 17(8): 1415-1418. DOI: 10.3980/j.issn.1672-5123.2017.8.06
Authors:Ihsan Yilmaz  Ferah Ozcelik  Gokhan Demir  Gonul Durusoy  Basak Saracoglu  Muhittin Taskapili
Affiliation:Beyoglu Eye Training and Research Hospital, Istanbul 34420, Turkey,Beyoglu Eye Training and Research Hospital, Istanbul 34420, Turkey,Beyoglu Eye Training and Research Hospital, Istanbul 34420, Turkey,Beyoglu Eye Training and Research Hospital, Istanbul 34420, Turkey,Beyoglu Eye Training and Research Hospital, Istanbul 34420, Turkey and Beyoglu Eye Training and Research Hospital, Istanbul 34420, Turkey
Abstract:AIM: To evaluate the comfort and visual performance of Rose K2 soft contact lenses in patients with keratoconus.

METHODS: Fifty eyes of 50 participants were included in this cross-sectional study. Each participant received a full ophthalmologic examination involving refraction, uncorrected visual acuity(UCVA), best spectacle corrected visual acuity(BCVA), slit-lamp biomicroscopy-fundoscopy, break-up time(BUT), corneal topography, and contrast sensitivity. After contact lens was fitted best contact lens corrected visual acuity(BCLCVA), contrast sensitivity, and comfort rating via visual analogue scales(VAS)were performed.

RESULTS: The mean age was 26.2±6.0(range: 16 to 39)y. The mean logMAR UCVA, BCVA, and BCLCVA with Rose K2 soft(in order)were 0.61±0.37(range: 0.15-1.3), 0.42±0.32(range: 0-1.3), and 0.18±0.20(range: 0-1.3). There were significant increases in visual acuities with contact lenses(P < 0.05). The mean contrast sensitivity scores were significantly better with both contact lens in mesopic and photopic conditions(P <0.05). The mean VAS score was 8.02±1.64(range: 5-10)for Rose K2 soft.

CONCLUSION: Rose K2 soft contact lens can improve visual acuity, contrast sensitivity with comfort in patients with keratoconus.

Keywords:contact lens   keratoconus   soft contact lens
本文献已被 万方数据 等数据库收录!
点击此处可从《国际眼科杂志》浏览原始摘要信息
点击此处可从《国际眼科杂志》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号