飞利浦电子显微镜控制电路原理及常见故障排除
引用本文:马继民 林玉峰 倪萍. 飞利浦电子显微镜控制电路原理及常见故障排除[J]. 医疗设备信息, 2007, 22(5): 84-85,75
作者姓名:马继民 林玉峰 倪萍
作者单位:南京军区福州总医院医学工程科,福建福州350025
摘    要:介绍了飞利浦电子显微镜电路结构各功能块的基本原理,并根据实践分析了电镜常见的故障原因及排除过程。

关 键 词:电子显微镜 电流调节 光纤
文章编号:1007-7510(2007)05-0084-02
收稿时间:2006-11-24
修稿时间:2006-11-24

Principle and Troubleshooting of Control Circuits in Philips Transmission Electron Microscope
MA Ji-min, LIN Yu-feng, Ni Ping. Principle and Troubleshooting of Control Circuits in Philips Transmission Electron Microscope[J]. Information of Medical Equipment, 2007, 22(5): 84-85,75
Authors:MA Ji-min   LIN Yu-feng   Ni Ping
Affiliation:Fuzhou General Hospital of Nanjing Area Command, Fuzhou Fujian 350025, China
Abstract:Describes the basic principle of circuit structure in Philips TEM and analyzes common malfunctions and their causes as well as the process in trouble shooting according to the experiences in maintenance.
Keywords:electronic microscope   current regulation   optical fibre