首页 | 本学科首页   官方微博 | 高级检索  
     


Biomechanical investigation of titanium elastic nail prebending for treating diaphyseal long bone fractures
Authors:Yen-Nien Chen  Pei-Yuan Lee  Chih-Wei Chang  Yi-Hung Ho  Yao-Te Peng  Chih-Han Chang  Chun-Ting Li
Affiliation:1.Department of BioMedical Engineering,National Cheng Kung University,Tainan,Taiwan;2.Department of Orthopedics,Show-Chwan Memorial Hospital,Changhua,Taiwan;3.Display Technology Center, Industrial Technology Research Institute,Hsinchu,Taiwan;4.Metal Industries Research & Development Centre,Kaohsiung,Taiwan;5.Graduate Institute of Mechatronic System Engineering,National University of Tainan,Tainan,Taiwan;6.Department of Orthopedics,National Cheng Kung University Hospital,Tainan,Taiwan
Abstract:This study numerically investigated the deformation of titanium elastic nails prebent at various degrees during implantation into the intramedullary canal of fractured bones and the mechanism by which this prebending influenced the stability of the fractured bone. Three degrees of prebending the implanted portions of the nails were used: equal to, two times, and three times the diameter of the intramedullary canal. Furthermore, a simulated diaphyseal fracture with a 5-mm gap was created in the middle shaft portion of the bone fixed with two elastic nails in a double C-type configuration. End caps were simulated using a constraint equation. To confirm that the simulation process is able to present the mechanical response of the nail inside the intramedullary, an experiment was conducted by using sawbone for validation. The results indicated that increasing the degrees of nail prebending facilitated straightening the nails against the inner aspect of canal after implantation, with increase in stability under torsion. Furthermore, reducing nail prebending caused a larger portion of the nails to move closer to the loading site and center of bone after implantation; the use of end caps prevented the nail tips from collapsing and increased axial stability. End cap use was critical for preventing the nail tips from collapsing and for increasing the stability of the nails prebent at a degree equal to the diameter of the canal with insufficient frictional force between the nail and canal. Therefore, titanium elastic nail prebending in a double C-type configuration with a degree three times the diameter of the canal represents a superior solution for treating transverse fractures without a gap, whereas that with a degree equal to the diameter of the intramedullary canal and combined with end cap use represents an advanced solution for treating comminuted fractures in a diaphyseal long bone fracture.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号