首页 | 本学科首页   官方微博 | 高级检索  
     


A meta-analysis of the effects of various interventions in preventing endotracheal suction-induced hypoxemia
Authors:Oh HyunSoo  Seo WhaSook
Affiliation:Department of Nursing, College of Medicine, Inha University, Incheon, Republic of Korea.
Abstract:The purpose of this study was to clarify the effects of interventions that were applied to prevent endotracheal suction-induced hypoxia by meta-analysis. To obtain a sample for this meta-analysis, a computerized search was performed through MEDLINE in addition to tracking down additional references cited in bibliographies of past reports. Finally thirty research reports were examined. In terms of the application time of oxygenation, insufflation and preoxygenation were the most prevalently used in the studies. Regarding the methods of oxygenation, the most prevalent technique for oxygenation was hyperoxygenation in combination with hyperinflation. Hyperoxygenation and hyperinflation were most frequently induced by FiO2 of 1 and a 150% tidal volume of three to six breaths, respectively. Suctioning was commonly sustained for <15 seconds using pressures of -80 to -120 mmHg and with size 14 French catheters. Insufflation was less effective than the other methods examined in the present study. From this study, it can be concluded that the interventions that were applied to prevent endotracheal suction-induced hypoxia, regardless of their application times or methods, reduced suction-induced hypoxia significantly.
Keywords:endotracheal suction  hyerventilation  hyperoxygenation  hypoxia  insufflation  preoxygenation
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号