首页 | 本学科首页   官方微博 | 高级检索  
检索        

ELISA一步法和二步法对HBsAg的检测结果比较
引用本文:李文萍.ELISA一步法和二步法对HBsAg的检测结果比较[J].山西职工医学院学报,2014(3):25-26.
作者姓名:李文萍
作者单位:汾西矿业集团总医院,山西介休032000
摘    要:目的:为了提高临床实验诊断的可信性和准确性,尽可能减少或避免出现假阳性和假阴性。质控要求必需对HBsAg酶免疫测定的方法进行比对。方法:采用ELISA 一步法和二步法对体检人群样本进行 HBsAg平行测定,结果不一致样本用 CLIA 重新检测。结果:一步法阳性检出率为10.12%;二步法阳性检出率为12.19%。一步法检测的阴性样本中,有20例二步法检测为阳性。结论:阳性检出率一步法相对较低,二步法较高;方法学比较亦显示二步法优于一步法,建议临床采用二步法检测HBsAg。

关 键 词:ELISA  HBsAg  CLIA

Detection Result Comparison of One-step and Two-step Method of ELISA to HBsAg
LI Wenping.Detection Result Comparison of One-step and Two-step Method of ELISA to HBsAg[J].Journal of Shanxi Medical College For Continuing Education,2014(3):25-26.
Authors:LI Wenping
Institution:LI Wenping (The General Hospital of Fenxi Mining, Jiexiu 032000, Shanxi, China)
Abstract:Objective:To enhance reliability and accuracy of clinical laboratory diagnosis to avoid false positive and false negative as much as possible. Comparison of HBsAg enzyme immunoassay method should be finished. Methods:The HBsAg parallel determination was made by means of one-step and two-step method of ELISA. For the specimens with different results,CLIA method to retest was adopted. Results:Based on the one-step method,the positive rate was 10. 12%;as to two-step method,the positive rate was 12. 19%. 20 cases of two-step method test were positive in the negative specimens of one-step method. Conclusions:The detection rate of one-step method is lower than two-step method test. Methodology comparison shows that two-step method is superior to one-step method. HBsAg two-step method is properly proposed in the clinical detection.
Keywords:ELISA  HBsAg  CLIA