首页 | 本学科首页   官方微博 | 高级检索  
     


Comparison of corneal endothelial changes following phacoemulsification with transversal and torsional phacoemulsification machines
Authors:Mustafa Ata?   Süleyman Demircan  Arzu Seyhan Karatepe Ha?ha?   Ahmet Gülhan  G?kmen Zarars?z
Affiliation:Department of Ophthalmology and Vision Sciences, Kayseri Traning and Research Hospital, Kocasinan-Kayseri 38010, Turkey;Department of Ophthalmology and Vision Sciences, Kayseri Traning and Research Hospital, Kocasinan-Kayseri 38010, Turkey;Department of Ophthalmology and Vision Sciences, Kayseri Traning and Research Hospital, Kocasinan-Kayseri 38010, Turkey;Department of Ophthalmology and Vision Sciences, Kayseri Traning and Research Hospital, Kocasinan-Kayseri 38010, Turkey;Department of Biostatistics, Faculty of Medicine, Erciyes University, Kocasinan-Kayseri 38010, Turkey
Abstract:

AIM

To compare and evaluate the phacoemulsification parameters and postoperative endothelial cell changes of two different phacoemulsification machines, each with different modes, but also to assess the relationship between postoperative endothelial cell loss and the phacoemulsification parameters, as well as the other factors in both groups.

METHODS

This prospective observational study was comprised of consecutive eligible cataract patients operated with phacoemulsification technique performed by the same surgeon using either a WHITESTAR Signature Ellips FX (transversal, group 1) or Infiniti OZil IP (torsional, group 2) machine.

RESULTS

The study included 86 patients. Baseline characteristics in the groups were similar. The median nuclear sclerosis grade was 3 (2-4) in the first group and 2 (2-4) in the second group (P=0.265). Both groups had similar phacoemulsification needle times (group 1: 60.63±36 s; group 2: 55.98±30 s; P=0.789). The percentage of endothelial cell loss 30d after surgery ranged from 3% to 15% with a median of 7% in group 1, and from 2% to 13% with a median of 6% in group 2; however, there was no statistically significant difference between the groups (P=0.407). Hexagonality (P=0.794) and the coefficient of variation (CV; P=0.142) did not differ significantly between the groups before and 30d after surgery. A significant positive correlation was found between the endothelial cell loss and nuclear sclerosis grade (group 1: P<0.001; group 2: P<0.001) and between the endothelial cell loss and average phacoemulsification power (group 1: P=0.007; group 2: P=0.008).

CONCLUSION

Both of these machines were efficient, with similar endothelial cell loss. This endothelial cell loss was related to the increased nuclear sclerosis grade and increased phacoemulsification power.
Keywords:endothelial cell changes   transversal, torsional   phacoemulsification
点击此处可从《国际眼科》浏览原始摘要信息
点击此处可从《国际眼科》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号