首页 | 本学科首页   官方微博 | 高级检索  
检索        


Simultaneous measurement of T1/B1 and pharmacokinetic model parameters using active contrast encoding (ACE)‐MRI
Authors:Jin Zhang  Kerryanne Winters  Olivier Reynaud  Sungheon Gene Kim
Institution:Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, USA
Abstract:The aim of this study was to assess the feasibility of combining dynamic contrast enhanced‐magnetic resonance imaging (DCE‐MRI) with the measurement of the radiofrequency (RF) transmit field B 1 and pre‐contrast longitudinal relaxation time T 10. A novel approach has been proposed to simultaneously estimate B 1 and T 10 from a modified DCE‐MRI scan that actively encodes the washout phase of the curve with different amounts of T 1 and B 1 weighting using multiple flip angles and repetition times, hence referred to as active contrast encoding (ACE)‐MRI. ACE‐MRI aims to simultaneously measure B 1 and T 10, together with contrast kinetic parameters, such as the transfer constant K trans, interstitial space volume fraction v e and vascular space volume fraction v p. The proposed method was tested using numerical simulations and in vivo studies with mouse models of breast cancer implanted in the flank and mammary fat pad, and glioma in the brain. In the numerical simulation study with a signal‐to‐noise ratio of 10, both B 1 and T 10 were estimated accurately with errors of 5.1 ± 3.5% and 12.3 ± 8.8% and coefficients of variation (CV) of 14.9 ± 8.6% and 15.0 ± 5.0%, respectively. Using the same ACE‐MRI data, the kinetic parameters K trans, v e and v p were also estimated with errors of 14.2 ± 8.3% (CV = 13.5 ± 4.6%), 14.7 ± 9.9% (CV = 13.3 ± 4.5%) and 14.0 ± 9.3% (CV = 14.0 ± 4.5%), respectively. For the in vivo tumor data from 11 mice, voxel‐wise comparisons between ACE‐MRI and DCE‐MRI methods showed that the mean differences for the five parameters were as follows: ΔK trans = 0.006 (/min), Δv e = 0.016, Δv p = 0.000, ΔB 1 = ?0.014 and ΔT 1 = ?0.085 (s), which suggests a good agreement between the two methods. When compared with separately measured B 1 and T 10, and DCE‐MRI estimated kinetic parameters as a reference, the mean relative errors of ACE‐MRI estimation were B 1 = ?0.3%, T 10 = ?8.5%, K trans = 11.4%, v e = 14.5% and v p = 4.5%. This proof‐of‐concept study demonstrates that the proposed ACE‐MRI method can be used to estimate B 1 and T 10, together with contrast kinetic model parameters.
Keywords:active contrast encoding  B1 mapping  contrast kinetic model  dynamic contrast enhanced MRI  T1 mapping
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号