Monte Carlo study of radial energy deposition from primary and secondary particles for narrow and large proton beamlet source models |
| |
Authors: | Peeler Christopher R Titt Uwe |
| |
Institution: | The University of Texas Graduate School of Biomedical Sciences at Houston, 6767 Bertner Avenue, S3.8344, Houston, TX 77030, USA. |
| |
Abstract: | In spot-scanning intensity-modulated proton therapy, numerous unmodulated proton beam spots are delivered over a target volume to produce a prescribed dose distribution. To accurately model field size-dependent output factors for beam spots, the energy deposition at positions radial to the central axis of the beam must be characterized. In this study, we determined the difference in the central axis dose for spot-scanned fields that results from secondary particle doses by investigating energy deposition radial to the proton beam central axis resulting from primary protons and secondary particles for mathematical point source and distributed source models. The largest difference in the central axis dose from secondary particles resulting from the use of a mathematical point source and a distributed source model was approximately 0.43%. Thus, we conclude that the central axis dose for a spot-scanned field is effectively independent of the source model used to calculate the secondary particle dose. |
| |
Keywords: | |