首页 | 本学科首页   官方微博 | 高级检索  
检索        


Development of an experimental apparatus for investigating lymphatic pumping activity of murine mesentery in vivo
Authors:Ono N  Mizuno R  Nojiri H  Ohhashi T
Institution:Department of Electronics and Control Engineering, Nagano National College of Technology, Japan.
Abstract:The present study has been attempted to establish a modified intravital microscope system for investigating murine lymphatic pumping activity in vivo and evaluate whether or not there is rhythmic pumping activity of murine mesenteric lymphatic vessels in vivo. We designed and constructed a custom organ chamber with a semicircular channel (8 mm in radius, 5 mm in width, 3 mm in depth), being suitable for the superfusing of murine mesentery in vivo. A marked lymphatic pumping activity was observed in the mesenteries of DDY mice. The maximal and minimal diameter and frequency in the pumping activity were 60.9 +/- 1.0 microm, 53.7 +/- 1.8 microm and 12.8 min(-1) (n = 5), respectively. Both NE (norepinephrine, 10(-8)-10(-6) M) and TEA (tetraethylammonium, 1-10 mM) caused dose-dependent constriction of the mesenteric lymphatic vessels in the mice. These findings suggest that a modified intravital microscope system with a specially designed and constructed edge-monitoring device enables us to investigate in vivo lymphatic circulation in murine mesenteries.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏