摘    要:目的建立一种辛伐他汀片中辛伐他汀含量的HPLC的测定方法。方法选用Techsphere ODS色谱柱(250 mm×4.6mm,5μm),乙腈-0.025%mol.L-1磷酸二氢钠溶液(pH=4.5)(65:35)为流动相,洗脱流速为1.0 ml·min-1,检测波长为238 nm。结果辛伐他汀在42.4~424.0 mg·L-1浓度范围内线性关系良好(r=0.999 6);平均回收率为99.6%,RSD=1.24%(n=6)。结论该方法简便,灵敏,易行,准确,适用于辛伐他汀的测定。

关 键 词:高效液相色谱法  辛伐他汀片

Determination of simvastatin in simvastatin tablets by HPLC
YUE Yi-tao.Determination of simvastatin in simvastatin tablets by HPLC[J].Anhui Medical and Pharmaceutical Journal,2011,15(9):1082-1083.
Authors:YUE Yi-tao
Institution:YUE Yi-tao(Huainan First People's Hospital,Huainan,Anhui 232007)
Abstract:Aim To establish an HPLC method for determination of simvastatin in simvastatin tablets.Methods TECHSPHERE ODS column(250 mm×4.6 mm,5 μm)was adopted,with acetonitrile-0.025mol·L-1sodium phosphate monobasic(pH=4.5)(65:35) as mobile phase.The detector wavelength was set at 238 nm,and the flow rate was 1.0 ml·min-1.Results Calibration curve was linear over the range of 42.4~424.0 mg·L-1(r=0.999 6).For potency assay the mean recovery was 99.6% with RSD as 1.24%(n=6).Conclusion The method is simple,sensitive and accurate.which was suitable for quantitative detection of simvastatin.