SPECT门控心肌灌注显像定量分析的诊断价值
引用本文:冯玉生,刘文官,顾宇参,朱玮珉,陈曙光,石洪成.SPECT门控心肌灌注显像定量分析的诊断价值[J].中国临床医学,2007,14(3):403-404.
作者姓名:冯玉生  刘文官  顾宇参  朱玮珉  陈曙光  石洪成
作者单位:1. 河南省南阳医专附属医院,河南南阳,473058
2. 复旦大学附属中山医院核医学科,上海,200032
摘    要:目的:探讨SPECT门控心肌灌注显像定量分析在提高诊断准确性方面的应用价值。方法:回顾分析112例具有完整的~(99m)Tc-MIBI门控静息/负荷心肌灌注显像资料和冠状动脉造影结果的患者资料。由3名有经验的核医学医师首先对SPECT心肌灌注显像的断层图像进行了分析并做出诊断,然后应用定量分析软件对门控图像进行定量分析获得左心室射血分数(LVEF)等功能指标并动态显示室壁运动情况,结合断层图像再次进行图像分析。以冠状动脉动脉造影的结果为标准,对比分析是否应用定量分析软件时诊断的敏感性、特异性和准确性。分析除LVEF外的其他功能性指标对诊断是否具有帮助。结果:112例患者冠状造影结果显示共计有147支冠状动脉管腔狭窄>50%。单纯SPECT心肌灌注显像断层图像目测分析诊断的敏感性、特异性和准确性分别为91.8%、86.8%和90.0%。综合分析断层图像与定量分析指标,诊断的敏感性、特异性和准确性分别为95. 9%、94.2%和94.9%。除LVEF外,其他定量分析指标被认为对诊断具有帮助的占59.8%(67/112),认为不确定者23.2%(26/ 112),认为没有价值者占17.0%(19/112)。结论:借助于定量分析软件可以明显的提高SPECT心肌灌注显像诊断的准确性。

关 键 词:心肌灌注显像  定量分析  诊断  准确性

Diagnostic Value of Quantification of Gated Myocardial Perfusion Imaging
FENG Yusheng,LIU Wenguan,GU Yushen,ZHU Weimin,CHEN Shuguang,SHI Hongchen.Diagnostic Value of Quantification of Gated Myocardial Perfusion Imaging[J].Chinese Journal Of Clinical Medicine,2007,14(3):403-404.
Authors:FENG Yusheng  LIU Wenguan  GU Yushen  ZHU Weimin  CHEN Shuguang  SHI Hongchen
Institution:1. The Affiliated Hospital of Nanyang Medical College in Henan Province, Nanyang 473058 ; 2. Department of Nuclear Medicine, Zhongshan Hospital ,Fudan University, Shanghai 200032
Abstract:Objective:To evaluate the diagnostic value of gated SPECT myocardial perfusion imaging using quantitative soft ware.Methods:Gated myocardial perfusion and coronary artery angiograms of 112 patients were reviewed.Firstly the tomo- graphies of myocardial perfusion imaging were analyzed by three experienced nuclear medicine physician.And then the tomo- graphies were analyzed again combined with the left ventricular functional information and observing the wall motion of left ven- tricular provided by quantitative software.Compare the diagnostic sensitivity,specificity and accuracy with or without quantita- tive software.Results:There were 147 coronary artery branches cavity st enoses more than 50% in 112 patients.The diagnostic sensitivity,specificity and accuracy with only slices of SPECT myocardial perfusion imaging was 91.8%,86.8% and 90.0%. The diagnostic sensitivity,specificity and accuracy combined slice of SPECT myocardial perfusion imaging with functional in- formation from quantitative software was 95.9%,94.2% and 94.9%.Except for the LVEF,others functional information such as end diastole volume and systole volume were considerate helpful in improving diagnostic accuracy in 59.8% cases.Con- clusion:Myocardial perfusion quantitative software was helpful in improving the diagnostic accuracy.