首页 | 本学科首页   官方微博 | 高级检索  
     

肠出血性大肠埃希菌O157∶H7环介导恒温扩增快速检测方法的建立与应用
引用本文:徐义刚,崔丽春,李苏龙,于恒纯,李丹丹,谢晓峰,姜艳春. 肠出血性大肠埃希菌O157∶H7环介导恒温扩增快速检测方法的建立与应用[J]. 中国人兽共患病杂志, 2010, 26(7): 618-623
作者姓名:徐义刚  崔丽春  李苏龙  于恒纯  李丹丹  谢晓峰  姜艳春
作者单位:徐义刚,李苏龙,于恒纯,谢晓峰,姜艳春,XU Yi-gang,LI Su-long,YU Heng-chun,XIE Xiao-feng,JIANG Yan-chun(黑龙江出入境检验检疫局检验检疫技术中心,哈尔滨,150001);崔丽春,CU Li-chun(东北林业大学,哈尔滨,150040);李丹丹,LI Dan-dan(海南出入境检验检疫局检验检疫技术中心,海口,570125) 
基金项目:国家质检总局科技计划项目,黑龙江省博士后基金 
摘    要:目的肠出血性大肠埃希菌(Enterohemorrhagic Escherichia coli,EHEC)O157∶H7是一种重要的人畜共患病致病菌,主要通过被污染的食物传播,引起出血性结肠炎,建立其快速检测方法具有重要意义。方法基于EHEC O157∶H7保守的rfbE基因序列,设计4条引物,利用环介导等温扩增技术(loop-mediatedisothermal amplification,LAMP),成功建立了EHEC O157∶H7LAMP快速检测方法 ,60min内即可完成致病菌检测。结果利用该LAMP方法对30种共38株细菌进行检测,所试EHEC O157∶H7均为阳性结果 ,说明该方法具有高度特异性。本方法对纯培养的EHEC O157∶H7检测限为12CFU/mL,污染食品中EHEC O157∶H7的检测限为18CFU/g。实践应用表明,对1121份进出口肉类、奶类制品及人工污染样品等进行检测,检出57份LAMP阳性,与采用AOAC标准检测结果的符合率为100%。结论该LAMP方法操作简便、特异性强、灵敏度高,具有良好的实用性。

关 键 词:肠出血性大肠埃希菌O157∶H7  rfbE基因  环介导恒温扩增  快速检测

Establishment of rapid method for detecting enterohemorrhagic E.coli O157:H7 by loop-mediated isothermal amplification
XU Yi-gang,CU Li-chun,LI Su-long,YU Heng-chun,LI Dan-dan,XIE Xiao-feng,JIANG Yan-chun. Establishment of rapid method for detecting enterohemorrhagic E.coli O157:H7 by loop-mediated isothermal amplification[J]. Chinese Journal of Zoonoses, 2010, 26(7): 618-623
Authors:XU Yi-gang  CU Li-chun  LI Su-long  YU Heng-chun  LI Dan-dan  XIE Xiao-feng  JIANG Yan-chun
Affiliation:1.Technical Centre of Heilongjiang Entry-exit Inspection and Quarantine Bureau,Harbin 150001,China;2.Northeast Forestry University,Harbin 150040,China;3.Technical Centre of Hainan Entry-exit Inspection and Quarantine Bureau,Haikou 570125,China)
Abstract:Enterohemorrhagic E.coli(EHEC)O157∶H7 is an important pathogen of zoonose,mainly initiates its transmission through contaminated food and causes hemorrhagic colitis.Thus,development of rapid method for detecting EHEC O157∶H7 is of great importance.According to highly conserved rfbE gene of EHEC O157∶H7,four primers were designed,then the method for detecting EHEC O157∶H7 was established by DNA loop-mediated isothermal amplification(LAMP),which could finish the test in 60 min.Thirty-eight bacteria strains were tested by the LAMP method and only EHEC O157∶H7 strains were LAMP positive results,indicating the high specificity of the method with detection limit of 12 CFU/mL for cultivated EHEC O157∶H7 and of 18 CFU/g for its contaminated food.In practice,57 portions of positive samples were detected from 1 121 portions of meat,dairy products and artificial contamination samples by the LAMP method,which accorded with the detection result from AOAC standard.It's indicated that the LAMP assay established in this study is a sensitive,rapid and simple tool for the detection of EHEC O157∶H7.
Keywords:EHEC O157∶H7  rfbE gene  LAMP  rapid detection
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号