首页 | 本学科首页   官方微博 | 高级检索  
     


Coregistered ventilation and perfusion SPECT using krypton-81m and Tc-99m-labeled macroaggregated albumin with multislice CT utility for prediction of postoperative lung function in non-small cell lung cancer patients
Authors:Ohno Yoshiharu  Koyama Hisanobu  Takenaka Daisuke  Nogami Munenobu  Kotani Yoshikazu  Nishimura Yoshihiro  Yoshimura Masahiro  Yoshikawa Takeshi  Sugimura Kazuro
Affiliation:Department of Radiology, Kobe University Graduate School of Medicine, Kobe, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe 650-0017, Japan. yosirad@kobe-u.ac.jp
Abstract:RATIONALE AND OBJECTIVE: Co-registered SPECT and CT imaging (SPECT-CT) has potential for more precise evaluation of regional pulmonary function and may be useful for prediction of postoperative lung function in non-small cell lung cancer (NSCLC) patients. The purpose of the present study was to prospectively assess the capability of co-registered SPECT-CT using krypton-81m (Kr-81m) and technetium-99m-labeled macroaggregated albumin (Tc-99m MAA) for prediction of postoperative lung function of NSCLC patients compared with SPECT and planar imaging. MATERIALS AND METHODS: Sixty consecutive patients considered candidates for lung resection underwent 16-slice CT, ventilation and perfusion scintigraphy with SPECT examinations, and preoperative and postoperative measurement of FEV(1)%. In each subject, SPECT and CT data were automatically fused by using commercially available software. Each postoperative FEV(1)% value was predicted from uptakes of Kr-81m and Tc-99m MAA within total and resected lungs. Then, reproducibility coefficients and the limits of agreement between actual and each predicted postoperative lung function were statistically assessed. RESULTS: Reproducibility coefficients of SPECT-CT (Kr-81m: 5.1%, Tc-99m MAA: 5.2%) were smaller than those of SPECT and planar image using Kr-81m (SPECT: 7.4%, planar image: 12.1%) and using Tc-99m MAA (SPECT: 7.2%, planar image: 11.8%). The limits of agreement for SPECT-CT (Kr-81m: 3.3 +/- 10.5%, Tc-99m MAA: 5.4 +/- 11.0%) were also smaller than that of SPECT and planar image and small enough for clinical purposes. CONCLUSIONS: Co-registered SPECT-CT using Kr-81m and Tc-99m MAA was able to more reproducibly and accurately predict postoperative lung function compared with SPECT and planar imaging.
Keywords:Lung   CT   functional imaging   SPECT   lung cancer
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号