摘    要:稳定性二氧化氯采用液体二元包装方式,贮存稳定。经活化后,二氧化氯浓度50mg/L的消毒液作用10min能完全杀灭细菌繁殖体,400mg/L作用5min能完全杀灭细菌芽胞.300mg/L作用5min能有效地破坏HBsAg抗原性。10%有机物对其杀菌作用无影响。该消毒液对人体无毒、无刺激性,但对金属有不同程度的腐蚀性。

关 键 词:二氧化氢  细菌  HBsAg  稳定性  腐蚀性  毒性

EXPERIMENTAL STUDY ON DISINFECTANT PERFOEMANCE AND TOxICITY OF STABILITY CHLORINE DIOXIDE.
GU Jian,et al..EXPERIMENTAL STUDY ON DISINFECTANT PERFOEMANCE AND TOxICITY OF STABILITY CHLORINE DIOXIDE.[J].Modern Preventive Medicine,1999,26(3):360-362.
Authors:GU Jian  
Abstract:The disinfactant of stability chlorine dioxide was used liquid two-kind-menthod bagged, and it was stable when itstored for a long time.After activated the microorganisms were killed completely when they were exposed to the disinfectant containing chlorine dioxide 50mg/L. for 10 minutes. and the bactera spores were killed thoroughly 400mg/L for 5 minutes. The antigemcity of HBsAg could be destroyed effectively when the disinfectant containing chlorine dioxide 300mg/L with 5 minutes contact time. There was no significant influence on germicidal efficacy of this chlorine disinfectant when 10% calf serum existed. This disinfectant was nontoxicity and non-irritant to human, but had a somewhat corrosion to the metal.