The effects of strapped spectacles on the fit factors of three manufactured brands of full facepiece negative pressure respirators.
Authors:T M Spear  R Hardgrove  J B Norman  D T Wulf  R J Rossi
Institution:School of Mines, Montana Tech of the University of Montana, Butte 59701-8997, USA.
Abstract:A study was conducted to determine the effects of strapped spectacles on the fit factors obtained during quantitative fit testing on three different brands of full facepiece negative pressure respirators. The three brands of respirators were evaluated with and without strapped spectacles worn by the test subjects. A total of 180 quantitative fit testing trials were conducted on ten male test subjects. For each test subject, three quantitative fit testing trials were performed with each brand of respirator with and without the spectacles. The average of the fit testing trials for each subject with each respirator was used for statistical analysis. The results demonstrated that the fit factor values were significantly lower during use of the spectacles (p < 0.05). The estimated percentage of test subjects who failed the American National Standards Institute pass/fail criteria for quantitative fit testing (1000) increased by 15-36% when spectacles were worn.